Search PubMed⌕ Search

PubMed · 4497722

Pitfalls in sterilization.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P L Jeffs. 1974. Pitfalls in sterilization.. https://pubmed.ncbi.nlm.nih.gov/4497722/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Appropriate range of quality control limit for wet deposition monitoring.

Precipitation chemistry programs in different regions of the world have different quality control limits for ion balance parameter IPD in wet deposition monitoring (R). The range of R values was calculated by assuming sample rainwater models in this paper. It was found that R was influenced by the inorganic ion types, total ion concentrations (IS) and the accuracy of the measurements (a(i)). R was defined and calculated as a function of a(i) and ion concentration C(i). R values of different types of wet deposition (including ocean type, continent type and combined oceanic and continental deposition) were different. There were also differences between the samples of the same type if the samples had different total ion concentrations. When IS>100 microeq/L, the ranges of R of ocean type deposition, continent type deposition and combined oceanic and continental deposition were 5 approximately 7%, 5 approximately 9% and 5 approximately 11%, respectively. When IS<50 microeq/L, if a(i) was 100%, the range of R was 33 approximately 71% because of the lower accuracy. It was also found that R of each criterion was in the range of R as calculated in this paper when IS>or=50 microeq/L, but when IS<50 microeq/L, the criteria varied greatly in their R values.

Quality Control↗

[Quality control (QC) of CT on rail system (FOCAL Unit) with a micro-multi leaf collimator (mMLC) using new GafChromic film for stereotactic radiotherapy].

PURPOSE: Recent years, CT on rail system was reported to be useful as a tool for image-guided radiotherapy (IGRT). This system was clinically developed with the aim of stereotactic irradiation (STI) for brain, lung, liver, prostate and other sites. Quality assurance and quality control (QC) is an important issue in CT on rail system to assure geometric accuracies. The purpose of this study is to estimate the geometric accuracies of our CT on rail system using a detachable micro-multi leaf collimator (mMLC) with new type radiochromic films. Carrying out our original QC program, translational errors, setup reproducibility, beam misalignment and beam characteristics were evaluated. METHODS AND MATERIALS: We have studied with CT on rail system (FOCAL unit, Toshiba Medical systems, Tokyo, Japan) and mMLC unit (Accuknife, Direx Inc., Tokyo, Japan). We have developed original alignment phantom and small steel markers (2 mm phi) were implanted on its surface at certain intervals. Firstly, we have evaluated the accuracy of self-moving CT gantry and CT resolutions for cranio-caudal directions by changing slice thickness. And then using the phantom, we have measured the accuracy and reproducibility of geometric isocenter of the linac side and the CT gantry side by scanning the phantom. We have also measured the geometric changes of the common treatment couch by weight-loaded test (up to 135 kgw). To estimate dosimetric and geometric accuracies with the mMLC unit, the misalignment of the beam axes (gantry, collimator and couch rotation axis), mMLC leaf positions, and dose distributions for the verification plan were measured with new type GafChromic films (GafChromic-RTQA, ISP Inc., USA) and cylindrical phantom. The dose characteristics of the GafChromic film were also evaluated. RESULTS: The reproducibility of the self-moving CT gantry have a good agreement within 1 mm. Weight-load test have shown a good reliability within 2 mm at the common treatment couch. The translational precision of the common treatment couch was 0.0 +/- 0.1 mm at linac side and -0.2 +/- 0.5 mm at CT gantry side. The misalignments of beam axes have been kept within 0.4 mm at maximum. Gap test have shown the accuracies of the mMLC leaf positions, which is needed to keep within 1 mm by a routine calibration. CONCLUSIONS: To practice quality control program for the FOCAL unit and the mMLC unit is essential for a regular interval to reduce systematic errors. New type radiochromic film would be useful for a verification tool as alternative to conventional film.

Quality Control↗

Analysis of cell-based RNAi screens.

RNA interference (RNAi) screening is a powerful technology for functional characterization of biological pathways. Interpretation of RNAi screens requires computational and statistical analysis techniques. We describe a method that integrates all steps to generate a scored phenotype list from raw data. It is implemented in an open-source Bioconductor/R package, cellHTS (http://www.dkfz.de/signaling/cellHTS). The method is useful for the analysis and documentation of individual RNAi screens. Moreover, it is a prerequisite for the integration of multiple experiments.

Quality Control↗