Search PubMedSearch

PubMed · 42617959

Hepatotoxicity of OBS: A review of the emerging PFOS substitute.

Abstract

As an alternative to perfluorooctanesulfonic acid (PFOS), sodium perfluorononenyl oxobenzene sulfonate (OBS) is widely used due to its cost-effectiveness. Multiple studies have shown that the liver is a classic target organ for OBS. However, there is currently no systematic review on the hepatotoxic effects of OBS. This review systematically summarizes the exposure characteristics of OBS in the environment and human populations, as well as its mechanisms of liver toxicity. In vivo studies consistently demonstrate that OBS induces hepatotoxic effects, such as hepatomegaly, vacuolization, elevated serum transaminases, and lipid dysregulation, though the manifestation of these phenotypes varies across species and exposure routes. In vitro evidence further shows that OBS reduces cell viability and survival, and triggers necrosis accompanied by inflammation. Mechanistically, oxidative stress, inflammatory signaling, and metabolism disorder are implicated. Critically, most existing work addresses subacute or subchronic exposure, leaving a gap in chronic risk assessment for long-term, low-dose OBS exposure. Moreover, mechanistic studies have focused predominantly on downstream transcriptional and signaling changes, with limited exploration of upstream epigenetic controls. Overall, this study aims to provide a comprehensive reference for future toxicological investigations and liver injury risk assessments related to OBS exposure.

Explore related subjects

Keep this discovery

BibTeXRIS

Haibo Jin, Mingyue Wang, Ting Tian, Tan Ma, Lili Yang, Hongliang Li, Jingyan Liang. 2026-08-19. Hepatotoxicity of OBS: A review of the emerging PFOS substitute.. https://doi.org/10.1016/j.toxlet.2026.113182

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related citations

Determination of 13 per- and polyfluoroalkyl substances in human plasma samples using LC-MS/MS: application to capillary microsamples.

Per- and polyfluoroalkyl substances (PFAS) are chemicals widely applied in industrial processes and highly persistent in the environment, whose extensive use has been linked to adverse health effects. Venous plasma is the conventional matrix for PFAS assessment in blood, and LC-MS/MS is the most used quantification technique. Despite the relevance of this topic, biomonitoring data on human exposure to PFAS in Brazil remain limited. This study validated an LC-MS/MS method for determination of 13 PFAS in human plasma. Blood samples were collected from volunteers by phlebotomy, followed by protein precipitation with acetonitrile containing 1% formic acid (v/v) and solid-phase extraction. Chromatographic separation was achieved on an Acquity UPLC HSS T3 column. The assay was linear over a calibration range of 0.2-20 ng/mL. Intra- and inter-assay precision (CV%) were within the ranges of 2.06-12.0% and 0.25-10.7%, respectively. As for accuracy, results were 89.0-112.9%. Matrix effect ranged from -1.31 to 0.05%. Stability after four freeze/thaw cycles and under autosampler conditions were also confirmed for all analytes. The method was applied to 40 paired venous and capillary plasma samples. Both measures exhibited high correlation (r = 0.926). PFOS was the only compound detected at concentrations ≥0.2 ng/mL (LLOQ) in all samples, with capillary plasma concentrations of 0.85-13.50 ng/mL. In summary, the method showed good validation performance and demonstrated the suitability of capillary plasma samples as an alternative matrix for PFAS quantification.

Humans

Developing low-carbon metered-dose inhalers: effects of propellant HFA-152a on mucociliary clearance and bronchoconstriction in two Phase 1 randomised trials.

BACKGROUND: To reduce the impact of respiratory care on climate change, metered-dose inhalers (MDIs) are being reformulated with low-global warming potential (GWP) propellants. Next-generation propellant hydrofluoroalkane (HFA)-152a has >90% lower GWP than HFA-134a. As part of the safety evaluation for HFA-152a, mucociliary clearance (MCC), bronchoconstriction and safety were compared with HFA-134a. METHODS: Two Phase 1, randomised, two-way crossover studies (NCT06506266/NCT06702462) were conducted. MCC study: healthy participants inhaled HFA-152a and HFA-134a in two 7-day sequences. MCC was quantified as area under radiolabelled particle retention time curve over 4 h (AUC0-4h) after nebulised 99mTc sulphur colloid, following each propellant. Bronchoconstriction study: patients with mild asthma inhaled single doses of HFA-152a and HFA-134a. Non-inferiority of HFA-152a versus HFA-134a was defined as percent change in FEV1 (litres), 15 min post dose (95% confidence intervals [CI]: lower limit >-10%, upper limit >0%). Both studies assessed safety. RESULTS: In 22 healthy participants, the impact on MCC did not differ between HFA-134a and HFA-152a (AUC0-4h geometric mean ratio [90% CI]: 1.00 [0.99, 1.01]). In 19 patients with mild asthma, neither HFA-152a nor HFA-134a induced bronchoconstriction (percent change in FEV1 at 15 min: -0.37% [HFA-152a] vs -0.60% [HFA-134a]); HFA-152a was non-inferior to HFA-134a (mean difference [95% CI]: 0.23% [-3.61, 4.07]). Adverse event (AE) rates were low and similar for both propellants in both studies; all AEs were mild, with no serious AEs or deaths. CONCLUSION: HFA-152a and HFA-134a had almost identical effects on MCC, neither induced bronchoconstriction, supporting MDI reformulation with the low-GWP propellant HFA-152a.

Humans