Search PubMed⌕ Search

PubMed · 414021

Baseline pulmonary physiologic values for the squirrel monkey (Saimiri sciureus).

Abstract

Baseline pulmonary physiologic values were determined on 43 (421-910 g) male and 47 (425-604 g) female squirrel monkeys (Saimiri sciureus). Respiratory rate was found to be 55 +/- 1.9 (SE) breaths per minute for males and 58 +/- 1.7 breaths per minute for females. Tidal volume was 8.9 +/- 0.37 ml for males and 7.5 +/- 0.28 ml for females. Airway resistance for the male was 0.052 +/- 0.006 cm H2O/ml/second; while for the female it was 0.086 +/- 0.011 cm H2O/ml/second. Dynamic compliance was found to be 1.78 +/- 0.15 ml/cm H2O for males and 1.48 +/- 0.124 ml/cm H2O for females. An index of distribution of ventilation was 48 +/- 2.5 breaths for males and 42 +/- 1.7 breaths for females.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C E Ulrich, R A Monaco, S M Messer. 1977. Baseline pulmonary physiologic values for the squirrel monkey (Saimiri sciureus).. https://pubmed.ncbi.nlm.nih.gov/414021/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental study.

OBJECTIVE: We tested whether the continuous monitoring of dynamic compliance could become a useful bedside tool for detecting the beginning of collapse of a fully recruited lung. DESIGN: Prospective laboratory animal investigation. SETTING: Clinical physiology research laboratory, University of Uppsala, Sweden. SUBJECTS: Eight pigs submitted to repeated lung lavages. INTERVENTIONS: Lung recruitment maneuver, the effect of which was confirmed by predefined oxygenation, lung mechanics, and computed tomography scan criteria, was followed by a positive end-expiratory pressure (PEEP) reduction trial in a volume control mode with a tidal volume of 6 mL/kg. Every 10 mins, PEEP was reduced in steps of 2 cm H2O starting from 24 cm H2O. During PEEP reduction, lung collapse was defined by the maximum dynamic compliance value after which a first measurable decrease occurred. Open lung PEEP according to dynamic compliance was then defined as the level of PEEP before the point of collapse. This value was compared with oxygenation (Pao2) and CT scans. MEASUREMENTS AND MAIN RESULTS: Pao2 and dynamic compliance were monitored continuously, whereas computed tomography scans were obtained at the end of each pressure step. Collapse defined by dynamic compliance occurred at a PEEP of 14 cm H2O. This level coincided with the oxygenation-based collapse point when also shunt started to increase and occurred one step before the percentage of nonaerated tissue on the computed tomography exceeded 5%. Open lung PEEP was thus at 16 cm H2O, the level at which oxygenation and computed tomography scan confirmed a fully open, not yet collapsed lung condition. CONCLUSIONS: In this experimental model, the continuous monitoring of dynamic compliance identified the beginning of collapse after lung recruitment. These findings were confirmed by oxygenation and computed tomography scans. This method might become a valuable bedside tool for identifying the level of PEEP that prevents end-expiratory collapse.

Airway Resistance↗

Use of an inspiratory impedance threshold valve during chest compressions without assisted ventilation may result in hypoxaemia.

INTRODUCTION: Although the concept of intermittent airway occlusion with the inspiratory impedance threshold valve (ITV) is a well-recognised strategy for improving efficiency of cardiopulmonary resuscitation (CPR), little is known about possible pulmonary side effects. METHODS: After a baseline chest CT-scan, 24 pigs with beating hearts undergoing apnoeic oxygenation received an injection of a contrast medium and were then assigned randomly to either active compression-decompression CPR with ITV (ACD ITV CPR), ACD CPR alone, or standard-CPR with ITV (standard-ITV CPR), or standard-CPR alone. After a maximum of 5 min of chest compressions or if oxygen saturation dropped below 70%, the experiment was stopped, haemodynamic variables and blood gas values were measured, and another CT-scan was performed; all animals underwent a 30 min recovery-period and a third subsequent CT-scan. RESULTS: At baseline arterial oxygen saturation by pulse oxymetry was 99% in all four groups; in both the ACD ITV CPR and the standard-ITV CPR groups, arterial oxygen saturation dropped below 70% within 126+/-9s, whereas chest compressions in all ACD CPR and standard-CPR pigs were performed over 5 min (P<0.001). Before stopping chest compressions arterial oxygen pressure decreased in the ACD ITV CPR group from 426+/-96 to 42+/-8 mmHg while it decreased in the ACD CPR group only from 415+/-116 to 197+/-127 mmHg (P<0.001 between groups); in the standard-ITV CPR group arterial oxygen partial pressure decreased from 427+/-109 to 34+/-5 mmHg while oxygen partial pressure decreased only from 467+/-44 to 144+/-98 mmHg in the standard-CPR group (P<0.004 between groups). After the second CT scan arterial oxygen partial pressure decreased further to 19+/-2 mmHg in the ACD ITV CPR versus 210+/-41 mmHg in the ACD CPR group; to 20+/-2 mmHg in the standard-ITV CPR versus 148+/-33 mmHg in the standard-CPR group. Lung-density values (Hounsfield units) were significantly higher in the ACD ITV CPR versus ACD CPR group (-134+/-54 versus -330+/-77) and standard-ITV CPR versus standard-CPR group (-98+/-50 versus -387+/-42). After a 30 min recovery-period, there were no significant differences in arterial oxygen partial pressure (ACD ITV CPR 275+/-110 mmHg versus ACD CPR 379+/-111 mmHg and standard-ITV CPR 265+/-138 mmHg versus standard CPR 367+/-55 mmHg). Furthermore, there were no differences in lung density values between groups after 30 min of recovery. CONCLUSION: In this animal model with a beating heart, intermittent airway obstruction through an ITV combined with apnoeic oxygenation and without active ventilation resulted in hypoxaemia due to transiently impaired lung function.

Airway Resistance↗