Search PubMedSearch

PubMed · 4128280

A simple multichannel preamplifier system with patch board.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M J Kloprogge, G A Hurkmans. 1973. A simple multichannel preamplifier system with patch board.. https://doi.org/10.3109/13813457309074482

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Characterization of an erbium-doped fiber amplifier as a light source and development of a near-infrared spectrophotometer based on the EDFA and an acoustooptic tunable filter.

A novel light source for the near-infrared region which has the highest intensity and widest spectral bandwidth of all near-IR light sources has been developed. The system is based on a single-mode fiber (about 18 m long) doped with Er3+ ion. The doped ion produces amplified spontaneous emission (ASE) in the near-IR region (from 1500 to 1600 nm) when it is excited by a diode laser at 980 nm. Because the diode laser is fusion-spliced directly to the doped fiber, the system is compact, all-solid-state, reliable, and stable and requires little maintenance. Its ASE output intensity was found to be comparable with those of diode lasers currently available for this near-IR region and is much higher than those of conventional halogen-tungsten lamps and the so-called (high-intensity) superluminescent light emitting diodes (SLEDs). Its spectral bandwidth is, however, much wider than those of the diode lasers and the SLEDs. Even higher intensity can be obtained from the doped fiber when a low-intensity (1 mW) light from a 1550-nm laser diode is introduced into the doped fiber. The intensity is enhanced (up to 7 times compared to the ASE) because the input light is amplified by the doped fiber. Furthermore, the output intensity of this erbium-doped fiber amplifier (EDFA) can be appropriately adjusted to provide relatively higher output intensity at any range of wavelengths (within this 1500-1600-nm region) by simply changing the temperature and/or the driven current of the input diode laser. Subsequently, an acoustooptic tunable filter was used to provide a means to spectrally tune the EDFA rapidly and to develop an all-solid-state, compact near-IR spectrophotometer which not only is very sensitive, stable, and reliable but also has a very high throughput. This spectrophotometer can detect water in ethanol at a limit of detection of 10 ppm. More importantly, the high through-put makes it possible to use the instrument to measure spectra of highly absorbing samples (e.g., absorption spectrum of 1.0 M Pr3+ aqueous solution through four sheets of paper); measurements which are currently not possible with halogen-tungsten lamp-based spectrophotometers.

Amplifiers, Electronic

Optimizing MRI signal-to-noise ratio for quadrature unmatched RF coils: two preamplifiers are better than one.

Using separate preamplifiers for the two outputs of a quadrature receive coil (and then combining the preamplifier outputs in a quadrature hybrid) provides a better signal-to-noise ratio (SNR) than is obtained by directly combining the quadrature outputs in a hybrid followed by a single preamplifier. The advantage of the two-preamplifier configuration increases when the body coil impedance changes and is no longer matched to 50 ohms. Using 0.4 dB noise figure preamplifiers, theory predicts 1.53, 0.42, 0, 0.42, and 1.53 dB SNR advantage of the two-preamplifier configuration over the one-preamplifier arrangement at body coil impedances of 12.5, 25, 50, 100, and 200 ohms, respectively. Experimental hot/cold resistor noise figure measurements indicate 2.86, 0.65, 0.36, 0.83, and 1.40 dB noise figure advantage for the two preamplifier configuration relative to the one-preamplifier configuration at those impedances. Empirical gains larger than theoretically calculated are attributable to insertion losses of various circuit elements, such as the quadrature hybrid, for the one-preamplifier configuration.

Amplifiers, Electronic

Maximizing signal-to-noise ratio in the presence of coil coupling.

Crosstalk due to coupling produces noise correlation between receiver coils. It has been stated that this correlation reduces the signal-to-noise ratio obtainable from combining signals from the coils. In this paper, it is shown that the effects of crosstalk on the signal-to-noise ratio may in theory be eliminated by properly combining signals. Equations are derived which show how the signals from two coils should be combined in the presence of crosstalk in order to obtain the same signal-to-noise ratio as in an ideal case of no crosstalk. The deviation from optimum signal-to-noise ratio due to imperfect circuits and amplifiers is discussed. An experimental technique for achieving the proper combination of signals is presented.

Amplifiers, Electronic