Abstract

The monofixateur opens up avenues in external skeleton fixation. Proceeding from Lambotte's groundwork and from the given anatomical conditions and biomechanical requirements, a system has been developed that ensures maximum effectiveness with a minimum of mechanical means and operative procedure. Of particular importance is the dual-application feature of the monofixateur system: it is equally indicated for static as well as dynamic fixation, and is quickly and easily adapted from one function to the other at any time as called for by the treatment process. This system provides for dynamic function when applied without fixation clamping jaws on one of the major bone fragments. It allows for functional axial compression to be exerted through muscle contraction and pressure, while simultaneously excluding the possibility of bending and rotation, thus effectively promoting the healing process. The monofixateur is indicated for treatment of closed, open and infected fractures, pseudarthrosis, osteotomy adaption, arthrodesis and joint transfixations. In brief, the advantages of external fixation by the monofixateur may be summarized as follows: Simple mechanical design affording precise function. High stability with small number of fixation components. Unilateral assembly of device in position biomechanically favorable. Static or dynamic fixation. Little patient impairment.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Gotzen, N Haas, R Schlenzka. 1985. [Progress in external fixation].. https://pubmed.ncbi.nlm.nih.gov/4075884/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Fractures of the long bones, pelvis and spine. Why these injuries should be operated on as soon as possible].

The article addresses the pathophysiological aspects connected to multiple trauma leading to organ damage. Several studies have shown that early operative stabilization of fractures is a lifesaving treatment involving less pulmonary complications, a shorter stay in hospital and lower hospital costs than operation at a late stage. The author also discusses guidelines for diagnosis and primary treatment of the fractures, and the timing and tactics of the final operative treatment. When the patient has been stabilized and injuries with higher priority (thoracic, abdominal and head injuries) have been successfully treated, it is recommended to operate major fractures as soon as possible (within 24 hours). It is necessary to have a liberal attitude to early operative treatment of minor fractures and injuries to ligaments, since these injuries might otherwise immobilize the patient and reduce the potential for physical restitution. The treatment of multi-traumatized patients imposes demands for extensive skills and experience, not only on the part of surgeons and anaesthetists, but also among the whole trauma team, including nurses in the operating theatre, anaesthetist nurses and nurses in the intensive care unit. This means that care of multi-traumatized patients should be centralized to experienced trauma units.

Femoral Fractures

Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures.

Owing to the continuous turnover of registrars and radiographers, most of the trauma-related orthopaedic surgery in this academic hospital is done by inexperienced surgeons-in-training and the fluoroscopy by junior radiographers. This could result in excessive radiation doses. Calibrated lithium fluoride thermoluminescent chips were secured to various parts of the primary surgeon's body to quantify the radiation dose received during the insertion of an intramedullary nail. Closed intramedullary fixation of 15 fractures of the femur was done with interlocking as necessary. The total average exposure time was 14 minutes 45 seconds per procedure. Distal locking took up 31% of this time. The mean radiation dose to the surgeon's eyes and thyroid was 0.13 mGy and to the dominant hand 2.10 mGy. This would allow the performance of about 350 such procedures per year before the maximum permissible dose level was reached. Recommendations to decrease irradiation dosage are made.

Femoral Fractures