Search PubMed⌕ Search

PubMed · 4064777

Value based interpretation of pulmonary function tests.

Abstract

Two contrasting errors in spirometric interpretation are the inappropriate conclusion of "normality" (type I) and of "abnormality" (type II). A survey of 67 health professionals showed major interpersonal and intersituational differences in opinion about the optimal relative proportions of type I and type II errors. This suggests the need for caution in the commonly employed practice of interpretation based on a 5 percent false positive rate.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Harber. 1985. Value based interpretation of pulmonary function tests.. https://doi.org/10.1378/chest.88.6.874

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Evaluation of single-tube osmotic fragility as a screening test for thalassemia.

A single-tube osmotic fragility test has been proposed for thalassemia screening with a range of different concentrations of saline having been employed. We have compared the sensitivity and specificity of 0.32%, 0.34%, and 0.36% buffered saline, and on the basis of our findings, recommend the use of 0.36% saline. This gave definitely positive or equivocal results in 81 of 85 patients with beta thalassemia trait and in 4 of 4 with alpha(0) thalassemia trait. There were 14% false positive results in hematologically normal patients and 81% of the samples from patients with various variant hemoglobins gave positive results. The sensitivity was 95% and specificity 86%. The single-tube osmotic fragility test is potentially useful in under-resourced laboratories although it cannot replace automated red cell indices using electronic counters.

False Positive Reactions↗

False-positive reduction in computer-aided diagnostic scheme for detecting nodules in chest radiographs by means of massive training artificial neural network.

RATIONALE AND OBJECTIVE: We developed a technique that uses a multiple massive-training artificial neural network (multi-MTANN) to reduce the number of false-positive results in a computer-aided diagnostic (CAD) scheme for detecting nodules in chest radiographs. MATERIALS AND METHODS: Our database consisted of 91 solitary pulmonary nodules, including 64 malignant nodules and 27 benign nodules, in 91 chest radiographs. With our current CAD scheme based on a difference-image technique and linear discriminant analysis, we achieved a sensitivity of 82.4%, with 4.5 false positives per image. We developed the multi-MTANN for further reduction of the false positive rate. An MTANN is a highly nonlinear filter that can be trained with input images and corresponding teaching images. To reduce the effects of background levels in chest radiographs, we applied a background-trend-correction technique, followed by contrast normalization, to the input images for the MTANN. For enhancement of nodules, the teaching image was designed to contain the distribution for a "likelihood of being a nodule." Six MTANNs in the multi-MTANN were trained by using typical nodules and six different types of non-nodules (false positives). RESULTS: Use of the trained multi-MTANN eliminated 68.3% of false-positive findings with a reduction of one true-positive result. The false-positive rate of our original CAD scheme was improved from 4.5 to 1.4 false positives per image, at an overall sensitivity of 81.3%. CONCLUSION: Use of a multi-MTANN substantially reduced the false-positive rate of our CAD scheme for lung nodule detection on chest radiographs, while maintaining a level of sensitivity.

False Positive Reactions↗