Search PubMed⌕ Search

PubMed · 4030807

A multipurpose tissue bending machine.

Abstract

A unique tissue bending machine was developed to test the bending properties of normal and bioprosthetic heart valve material. It can be operated in air or in a tissue bath and can measure bending torques with an accuracy in excess of 1.0 microN m. Three contrasting substances were tested to compare their stiffness and to demonstrate the machine.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I Vesely, D R Boughner. 1985. A multipurpose tissue bending machine.. https://doi.org/10.1016/0021-9290(85)90665-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

On the stall force for growing microtubules.

The assembly of microtubules generates forces that play a role in cellular motility processes such as the motion of chromosomes during mitosis. Recently, Mogilner and Oster proposed a model for the growth of microtubules that agrees quantitatively with the force-velocity relation measured for individual microtubules. In addition, the authors predicted that the stall force for any polymer consisting of N independently growing protofilaments should increase as the square root of N. We simulated this model and found that the stall force increases linearly with N, and is in fact consistent with the maximum force predicted by thermodynamic arguments. We show that this discrepancy can be explained by a more careful treatment of the "off-term" in the Mogilner-Oster model.

Biophysics↗

Steady-state gel electrophoresis of long polymer molecules: a theoretical study.

The velocity of long polymer molecules in a gel and the liquid flow profile in the vicinity of a molecule's surface were studied theoretically by combining the Navier-Stokes equation with the Poisson-Boltzmann equation. The electrophoretic mobility has been calculated in dependence of the ionic strength of the electrolyte solution, its viscosity, the gels' volume friction coefficient, the surface charge and the radius of the polymer molecule. The results are presented in a nondimensional form and depend on two dimensionless parameters only. The first parameter is the radius of the polymer molecule in units of the Debye length. The second is a parameter comprising the electrolyte's viscosity and the gel density. Thus, by similarity theory, the results apply to any given experimental arrangement.

Biophysics↗

Barometers and bladders: a primer on pressures.

PURPOSE: We develop a "consilient" (unified) view of pressure as a physical phenomenon and "clinimetric" tool, making a connection between barometers and bladders. MATERIALS AND METHODS: The philosophy, physics and clinical applications of pressure during the last 2 millennia were examined from Lucretius to the modern medical subspecialties. RESULTS: A variety of units and systems of pressure quantification developed as the physics of pressure became understood. Applications of pressure in clinical medicine with distinct physiological relevance have been created for organ systems across the subspecialties. Some measurements have become useful for management of urinary tract and other diseases. CONCLUSIONS: Despite a broad range of units, systems and applications, a consilient view of pressure in medicine can be approached. This perspective is fundamental to understanding the significance of pressures in the expanding clinimetric arena and should mitigate against misplaced concreteness that is tempting in modern medical practice, whereby laboratory tests become virtual realities and are mistaken for patients.

Biophysics↗