Search PubMed⌕ Search

PubMed · 4009829

Improved continuous flow transurethral prostatectomy.

Abstract

We compared 2 continuous flow resectoscopes for transurethral resection of the prostate--a new intrinsic bladder pressure-controlled drainage system and the suction drainage system. In 31 patients undergoing transurethral prostatic resection who were assigned randomly to a pressure-controlled (17) or suction drainage (14) resectoscope group the required irrigant volume and operative blood loss (milliliter per gram resected tissue) were appreciably less with pressure-controlled drainage, while the resection rate (gram per minute) was significantly greater. Irrigant absorption, as evidenced by weight gain and changes in hematocrit, serum osmolality and serum sodium, was minimal in either group, with no significant difference between the 2 methods. In addition, there was no significant difference in intraoperative intravesical pressure between the 2 groups. The suction drainage system led to pump drainage failure in certain rotational positions, resulting in diminished visibility and increased resection time. The pressure-controlled drainage system required no suction devices or adjustments, thus, allowing constant improved visibility and uninterrupted resection. These results suggest that the efficiency and ease of transurethral prostatic resection are superior with the pressure-controlled continuous flow drainage system than with the suction drainage system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P N Bretan, P R Carroll, R D McClure, R D Williams. 1985. Improved continuous flow transurethral prostatectomy.. https://doi.org/10.1016/s0022-5347(17)46988-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Traditional Foley drainage systems--do they drain the bladder?

PURPOSE: Foley catheters are assumed to drain the bladder to completion. Drainage characteristics of Foley catheter systems are poorly understood. To investigate unrecognized retained urine with Foley catheter drainage systems, bladder volumes of hospitalized patients were measured with bladder scan ultrasound volumetrics. Additionally, an in vitro bench top mock bladder and urinary catheter system was developed to understand the etiology of such residual volumes. A novel drainage tube design that optimizes indwelling catheter drainage was also designed. MATERIALS AND METHODS: Bedside bladder ultrasound volumetric studies were performed on patients hospitalized in ward and intensive care unit. If residual urine was identified the drainage tubing was manipulated to facilitate drainage. An ex vivo bladder-urinary catheter model was designed to measure flow rates and pressures within the drainage tubing of a traditional and a novel drainage tube system. RESULTS: A total of 75 patients in the intensive care unit underwent bladder ultrasound volumetrics. Mean residual volume was 96 ml (range 4 to 290). In 75 patients on the hospital ward mean residual volume was 136 ml (range 22 to 647). In the experimental model we found that for every 1 cm in curl height, obstruction pressure increased by 1 cm H2O within the artificial bladder. In contrast, the novel spiral-shaped drainage tube demonstrated rapid (0.5 cc per second), continuous and complete (100%) reservoir drainage in all trials. CONCLUSIONS: Traditional Foley catheter drainage systems evacuate the bladder suboptimally. Outflow obstruction is caused by air-locks that develop within curled redundant drainage tubing segments. The novel drainage tubing design eliminates gravity dependent curls and associated air-locks, optimizes flow, and minimizes residual bladder urine.

Drainage↗