Abstract

The measurement process in fluorophotometry inherently involves a loss of information due to the finite sampling volume of the instrument. Mathematically, the effect is expressed as a convolution of the actual fluorescein distribution with the spread function of the instrument. Scattering by the ocular media can increase the spread function over that due to the instrument alone. A method is proposed for deconvolution of vitreous fluorophotometry data. Simulation studies and analyses of patient data demonstrate recovery of information with this method, including enhancement of retinal peaks and resolution of detail in the posterior vitreous which was not apparent from the original scans.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R T Smith, C J Koester, C J Campbell. 1986. Vitreous fluorophotometer data analysis by deconvolution.. https://pubmed.ncbi.nlm.nih.gov/3949469/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Funnel plots, performance variation and the Myocardial Infarction National Audit Project 2003-2004.

BACKGROUND: Clinical governance requires health care professionals to improve standards of care and has resulted in comparison of clinical performance data. The Myocardial Infarction National Audit Project (a UK cardiology dataset) tabulates its performance. However funnel plots are the display method of choice for institutional comparison. We aimed to demonstrate that funnel plots may be derived from MINAP data and allow more meaningful interpretation of data. METHODS: We examined the attainment of National Service Framework standards for all hospitals (n = 230) and all patients (n = 99,133) in the MINAP database between 1st April 2003 and 31st March 2004. We generated funnel plots (with control limits at 3 sigma) of Door to Needle and Call to Needle thrombolysis times, and the use of aspirin, beta-blockers and statins post myocardial infarction. RESULTS: Only 87,427 patients fulfilled criteria for analysis of the use of secondary prevention drugs and 15,111 patients for analysis by Door to Needle and Call to Needle times (163 hospitals achieved the standards for Door to Needle times and 215 were within or above their control limits). One hundred and sixteen hospitals fell outside the 'within 25%' and 'more than 25%' standards for Call to Needle times, but 28 were below the lower control limits. Sixteen hospitals failed to reach the standards for aspirin usage post AMI and 24 remained below the lower control limits. Thirty hospitals were below the lower CL for beta-blocker usage and 49 outside the standard. Statin use was comparable. CONCLUSION: Funnel plots may be applied to a complex dataset and allow visual comparison of data derived from multiple health-care units. Variation is readily identified permitting units to appraise their practices so that effective quality improvement may take place.

Data Display↗

Thin-section CT of the lungs: eye-tracking analysis of the visual approach to reading tiled and stacked display formats.

OBJECTIVE: To use eye-tracking analysis to identify the differences in approach to and efficiency of reading thin-section CT of the lungs presented tiled and stacked soft-copy displays. MATERIALS AND METHODS: Four chest radiologists read 16 thin-section CT examinations displayed in either a tiled (four images at once) or stacked (full screen cine) format. Eye-movements were recorded and analysed in terms of movement type; saccade distance (classified by the calculated range of useful peripheral vision), number of fixations, duration and direction of gaze-comparison of the areas of the images viewed. RESULTS: Cases presented in stacked format were read quicker than when presented in tiled format with a greater fixation frequency (5 fixations versus 4.5 fixations points per 100 data points; p<0.001) and a greater proportion of short saccades (97% versus 94%; p<0.005). The consistency with which the observers viewed equivalent areas of the scan images in different cases was greater when viewing in stacked format (mean kappa 0.45 versus 0.36; p<0.05) suggesting a more systematic approach to reading. CONCLUSION: Eye-tracking data demonstrates why thin-section CT examinations of the lungs are read more efficiently when displayed in a stack as opposed to a tiled format.

Data Display↗