Search PubMed⌕ Search

PubMed · 3917790

Simplifying infusion calculations.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R J Brooks, A M Wilson. 1985-01-26. Simplifying infusion calculations.. https://doi.org/10.1136/bmj.290.6464.291

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Novel approach for the analysis of glycated hemoglobin using capillary isoelectric focusing with chemical mobilization.

In this work, a novel CIEF methodology for the analysis of the glycated hemoglobin, HbA(1c), in dimethylpolysiloxane coated fused-silica capillaries (DB-1, 50 microm I.D., 27 cm, 0.20 microm coating thickness), using a narrow pH ampholyte mixture (4% pH 6-8:pH 3-10, 10:1, v/v) in 0.30% methylcellulose, was developed. In the focusing procedure, a 0.100-mol l(-1) phosphoric acid solution was used as anolyte and a 0.040-mol l(-1) NaOH solution was used as catholyte. During method development, two types of mobilization of the focused hemoglobins were tested: pressure and chemical mobilization. Chemical mobilization performed better, allowing the complete baseline resolution of the hemoglobin of interest, HbA(1c), from its adjacent peak, HbA, in less than 8 min. In the chemical mobilization procedure, the catholyte was replaced by a 0.040-mol l(-1) NaOH solution containing 0.080 mol l(-1) NaCl. The proposed methodology was applied to the analysis of 31 hemolysate samples and validated with respect to the selectivity, inter-assay and intra-assay precision (both migration time and hemoglobin percentage concentration). In addition, HbA(1c) determinations were compared for the CIEF method and a chromatographic standardized procedure using cation-exchanger columns (Variant, Bio-Rad), adopted in a local clinical laboratory, showing excellent correlation (r(2)=0.872, n=31). The slope was found to be statistically equal to one but the intercept differed from zero. Also the Bland-Altman plot indicates bias, implying that the CIEF method yields HbA(1c) concentration higher than the reference method. The separation of the hemoglobins HbA, HbA(2), HbF and HbA(1c) and the variants HbS and HbC was also demonstrated (8 min run). The resolving power of the proposed CIEF method allowed baseline resolution of hemoglobins with a pI difference as small as ca. 0.03, as it is the case for the pairs HbC/HbA(2) and HbA/HbA(1c).

Calibration↗

Improved method for plasma malondialdehyde measurement by high-performance liquid chromatography using methyl malondialdehyde as an internal standard.

Measurement of malondialdehyde (MDA) is an important contribution to the assessment of oxidative stress. We report a sensitive and reproducible high-performance liquid chromatography (HPLC) method for measurement of plasma MDA in the assessment of lipid peroxidation. Using methyl malondialdehyde (Me-MDA) as an internal standard with reversed-phase HPLC and UV detection and derivatisation with 2,4 dinitrophenylhydrazine (DNPH), we obtained maximum MDA values with 60-min incubation of 10% plasma with 1 M NaOH at 60 degrees C. The dilution of the plasma and a longer incubation time in the alkaline hydrolysis step greatly improved recovery of MDA from its bound form. Ratios of peak height of MDA/Me-MDA were linear over a range of 0-100 microM with correlation coefficients >0.99. The recovery was 88.5%. Within and between run variations were <4 and <7%, respectively. The mean MDA value measured in 20 healthy volunteers was 13.8 microM (+/-1.32).

Calibration↗

Determination of serum thyroxine enantiomers in patients by liquid chromatography with a chiral mobile phase.

A chromatographic method for the separation and determination of D- and L-thyroxine enantiomers (D-, and L-T4) in human serum with a chiral ligand ion-exchange system using a chiral mobile phase additive and a silica column was established. An aqueous eluent containing L-proline (L-pro) sufficiently complexed copper II ions and triethylamine (TEA) was used. It was monitored with a UV detector. The separation was completed in 12 min. The method has acceptable sensitivity, precision and accuracy for analysis. The limit of detection and the limit of quantitation for both D- and L-T4 were 0.1 microg/ml and 0.8 microg/ml, respectively. Calibration curves were linear within 1-100 microg/ml; the mean correlation coefficients were r(D-T4)=0.9986 for D-T4 and r(L-T4)=0.9978 for L-T4. T4 enantiomers were separated on baseline under the optimum condition. L-T4 eluted before D-T4. The concentration of D-T4 and L-T4 in 45 thyroid patients serum (hyperthyroid, hypothyroid, thyroidectomy, goitre or thyroiditis) using HPLC was determined, those results showed that D,L-T4 concentration varied in different thyroid patient. Attention should be paid to this result in treating thyroid disease in the clinic.

Calibration↗