Laboratory accuracy in casting removable partial denture frameworks.

Abstract

An attempt was made to compare the clinical accuracy of two types of cast metals used in the fabrication of removable partial dentures as they were prepared by commercial laboratories. No comparison of the metals could be made, because the discrepancies that were found were too gross and were related to technical error. Suprabulge clasps were placed in less undercut than prescribed. Infrabulge clasps were placed in more undercut than prescribed. The laboratories produced better accuracy when they were informed of the purpose of the cast frameworks than when the frameworks were made without the knowledge that their work would be tested. One laboratory produced better results than the other under similar conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D N Firtell, A M Muncheryan, A J Green. 1985. Laboratory accuracy in casting removable partial denture frameworks.. https://doi.org/10.1016/0022-3913(85)90488-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Zonal coulometric analysis of the corrosion resistance of dental alloys.

OBJECTIVES: The corrosion resistance of a series of 51 dental alloys and pure metals was evaluated by coulometric analysis. METHODS: The method consisted of dividing the anodic polarization curves into three separate zones: zone I, from the open-circuit potential (after 24 h immersion) up to +300 mV (SCE): zone II, from 300 mV to 700 mV (SCE): zone III, +700 mV to 1000 mV (SCE). The surfaces below the curves are integrated for each zone and the results expressed in millicoulombs (mC). RESULTS AND CONCLUSIONS: Although the intensity of degradation in the mouth may vary from patients to patient, we think that a potential danger may occur in zones I and II in particular. Coulometric analysis reveals that: (i) the alloys for the porcelain-fused-to metal (PFM) technique have a better corrosion resistance (2.58 mC on average for the sum of the three zones, against 283.7 mC for conventional alloys): (ii) the elements Cu, Ag and Ni reduce the corrosion resistance of gold-based alloys: (iii) within the same class, single-phase alloys resist better than two-phase alloys.

Chromium Alloys

Effect of two opaquing techniques and two metal surface conditions on metal-ceramic bond strength.

The optimal conditions for opaquing techniques during porcelain application have not been confirmed. In this study the metal-ceramic bond strength was measured among one porcelain and three dental alloys, namely a gold-platinum-palladium alloy, a silver-free gold-palladium alloy, and a base metal alloy, with two opaquing techniques (a single masking layer versus a thin overfired layer followed by a second masking layer). In addition, the opaque porcelain was fired over an oxidized and nonoxidized alloy surface for the silver-free gold-palladium alloy. No significant differences in bond strength were recorded between the two opaquing techniques with the gold-platinum-palladium and base metal alloys. There was no substantial differences between the two opaquing techniques when opaque was applied over an oxidized gold-palladium alloy surface and bond strengths were substantially greater over an oxidized surface. However, when the opaque was applied to a nonoxidized gold-palladium surface the two-layer technique created a significantly greater bond strength.

Chromium Alloys