Search PubMed⌕ Search

PubMed · 3899151

Valvar prosthetic dysfunction. Localisation and evaluation of the dysfunction using the Doppler technique.

Abstract

Thirty patients with 33 mitral or aortic prostheses or both were examined using the pulsed Doppler technique combined with cross sectional echocardiography to study the applicability of the Doppler technique in the diagnosis and evaluation of the severity of prosthetic dysfunction and to assess the ability of the mapping procedure to estimate the site and the size of the prosthetic defect. The dysfunction was valvar regurgitation in 29 instances and stenoses in eight, all of which were confirmed by invasive procedures. The severity of the dysfunction was graded on a three point scale. A control group of 73 subjects with 88 normal prostheses also underwent pulsed Doppler and cross sectional echocardiography. The pulsed Doppler study followed the usual procedure for a valvar disease including two and three dimensional mapping for regurgitation. Eight patients also underwent a continuous wave Doppler examination. The diagnostic reliability of the pulsed Doppler technique was greater than or equal to 90%. The severity of the dysfunction was accurately assessed in 86% of cases. In the case of aortic regurgitation, mapping of the jets was performed as easily for prostheses as for native regurgitant valves. In the case of mitral regurgitation, the mapping patterns depended on the cause of the dysfunction. With valvar tears, a jet was detected at the centre of the annulus, and with paravalvar leaks eccentric atrial jets were seen opposite the site of the leak. The pulsed Doppler and the surgical findings correlated well for both the site of the dysfunction (16/20 (80%) patients) and the size of the leak (13/16 (81%) patients). Thus, despite some limitations, pulsed Doppler and particularly the mapping procedure provide sufficient information to give an accurate non-invasive assessment of prosthetic valve dysfunction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Veyrat, S Witchitz, A Lessana, A Ameur, G Abitbol, D Kalmanson. 1985. Valvar prosthetic dysfunction. Localisation and evaluation of the dysfunction using the Doppler technique.. https://doi.org/10.1136/hrt.54.3.273

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Right-sided vegetation unmasks aortic endocarditis.

Echocardiography is a key tool in the diagnosis of infective endocarditis. Although transthoracic echocardiography is the first step in the work-up, transoesophageal echocardiography is mandatory for the evaluation of the exact extent of the infectious process. Indeed, perivalvular abscess can fistulate towards different heart chambers, leading sometimes to critical clinical situations.

Aortic Valve↗

Aortic translocation for the management of transposition of the great arteries with a ventricular septal defect, pulmonary stenosis, and hypoplasia of the right ventricle.

A 2-month-old patient with transposition of the great arteries, a ventricular septal defect, pulmonary stenosis, and severe hypoplasia of the right ventricle successfully underwent a biventricular repair utilizing the aortic translocation technique. Advantages of this surgical repair over the Rastelli procedure in the management of this complex congenital heart lesion are discussed.

Aortic Valve↗

Evidence in favor of linkage to human chromosomal regions 18q, 5q and 13q for bicuspid aortic valve and associated cardiovascular malformations.

The aim of this study was to identify regions of the genome that harbor genes influencing inheritance of bicuspid aortic valve (BAV) and/or associated cardiovascular malformation (CVM). Aortic valve disease is an important clinical problem, which often results in valve replacement, the second most common cardiac surgery in the United States. In every age group, a majority of cases of valve disease involves a BAV. BAV is the most common CVM with a reported prevalence of 1-2%. Heritability studies indicate that BAV determination is almost entirely genetic. We used a family-based genome-wide linkage analysis with microsatellite markers. Parametric and nonparametric analyses were performed with the software GENEHUNTER and SOLAR (Sequential Oligogenic Linkage Analysis Routines). Thirty-eight families (353 subjects) with BAV and/or associated CVM were assessed. Each participant underwent a standardized echocardiographic examination. The highest LOD score, 3.8, occurred on chromosome 18q between markers D18S68 and D18S1161. Two other chromosomal regions, 5q15-21 (between D5S644 and D5S2027) and 13q33-qter (between D13S1265 and 13qter), exhibited suggestive evidence of linkage (LOD > 2.0). Further, two previously reported linkage peaks on 9q34 and 17q24 were replicated in family specific analyses. No significant X chromosome linkage peaks were identified. In this genome-wide scan we demonstrate for the first time, that BAV and/or associated CVM exhibit linkage to chromosomes 18q, 5q and 13q. These regions likely contain genes whose mutation results in BAV and/or associated CVM indicating their important role in valvulogenesis and cardiac development.

Aortic Valve↗