Search PubMedSearch

PubMed · 3874518

Electrical tinnitus control.

Abstract

A new method of electrical tinnitus control employs sine-wave frequencies, slowly varying between 0.2 and 20 kHz and modulating a 60 kHz carrier. The latter literally carries the audio-frequencies "under the skin" via external electrodes placed on both mastoids. Patients undergo exposure at home. The dosis increases from 1 h/day to maximally 5 h/day. Suppression is achieved in about 60% of selected patients. Once tinnitus is under control, usually after 3-5 sessions, exposure may be reduced.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Shulman, J Tonndorf, B Goldstein. Electrical tinnitus control.. https://doi.org/10.3109/00016488509108916

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Model-based development of neuroprosthesis for paraplegic patients.

In paraplegic patients with upper motor neuron lesions the signal path from the central nervous system to the muscles is interrupted. Functional electrical stimulation applied to the lower motor neurons can replace the lacking signals. A so-called neuroprosthesis may be used to restore motor function in paraplegic patients on the basis of functional electrical stimulation. However, the control of multiple joints is difficult due to the complexity, nonlinearity, and time-variance of the system involved. Furthermore, effects such as muscle fatigue, spasticity, and limited force in the stimulated muscle further complicate the control task. Mathematical models of the human musculoskeletal system can support the development of neuroprosthesis. In this article a detailed overview of the existing work in the literature is given and two examples developed by the author are presented that give an insight into model-based development of neuroprosthesis for paraplegic patients. It is shown that modelling the musculoskeletal system can provide better understanding of muscular force production and movement coordination principles. Models can also be used to design and test stimulation patterns and feedback control strategies. Additionally, model components can be implemented in a controller to improve control performance. Eventually, the use of musculoskeletal models for neuroprosthesis design may help to avoid internal disturbances such as fatigue and optimize muscular force output. Furthermore, better controller quality can be obtained than in previous empirical approaches. In addition, the number of experimental tests to be performed with human subjects can be reduced. It is concluded that mathematical models play an increasing role in the development of reliable closed-loop controlled, lower extremity neuroprostheses.

Electric Stimulation Therapy

Implantable spinal cord stimulator to treat the ischemic manifestations of thromboangiitis obliterans (Buerger's disease).

Thromboangiitis obliterans (Buerger's disease) is a segmental inflammatory vasculitis that involves the small-sized and medium-sized arteries, veins, and nerves. It is causally related to tobacco use. The diagnosis is usually made on the basis of the presence of distal arterial disease in individuals who smoke and in whom other disease entities have been excluded. The most effective treatment for Buerger's disease is smoking cessation. Without strict adherence to tobacco avoidance, disease progression is likely. Methods to control ischemic pain include medications, sympathectomy, or surgical revascularization. The effect of sympathectomy is unpredictable, and the chances of a successful revascularization procedure are rare because distal target vessels often are extensively diseased. Herein, we describe a patient whose condition did not respond to the usual conservative therapy but did respond dramatically to the implantation of a permanent spinal cord stimulator. Although these devices have been used for more than 20 years in various other peripheral arterial diseases, their use in Buerger's disease has been limited.

Electric Stimulation Therapy