Search PubMed⌕ Search

PubMed · 3847301

Transudative pleural effusions.

Abstract

A transudative pleural effusion develops when the systemic factors influencing the formation or absorption of the pleural fluid are altered. The pleural surfaces are not involved by the primary pathologic process. The diagnosis of transudative effusion is simple to establish by examining the characteristics of the pleural fluid. Transudates have all of the following three characteristics: The ratio of the pleural fluid to the serum protein is less than 0.5. The ratio of the pleural fluid to the serum LDH is less than 0.6. The pleural fluid LDH is less than two thirds the upper limit of normal for the serum LDH. Among the conditions that produce transudative pleural effusion, congestive heart failure is by far the most common. Pulmonary embolism, cirrhosis of the liver with ascites, and the nephrotic syndrome are the other common causes. Management of transudative pleural effusions involves managing the primary disease. Refractory, massive effusions can be controlled by tetracycline pleurodesis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K G Chetty. 1985. Transudative pleural effusions.. https://pubmed.ncbi.nlm.nih.gov/3847301/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stopped-flow enzyme assays on a chip using a microfabricated mixer.

This paper describes a microfabricated enzyme assay system including a micromixer that can be used to perform stopped-flow reactions. Samples and reagents were transported into the system by electroosmotic flow (EOF). Streams of reagents were merged and passed through the 100-pL micromixer in < 1 s. The objective of the work was to perform kinetically based enzyme assays in the stopped-flow mode using a system of roughly 6 nL volume. Beta-galactosidase (beta-Gal) was chosen as a model enzyme for these studies and was used to convert the substrate fluorescein mono-beta-D-galactopyranoside (FMG) into fluorescein. Results obtained with microfabricated systems using the micromixer compared well to those obtained with an external T mixing device. In contrast, assays performed in a microfabricated device by merging two streams and allowing mixing to occur by lateral diffusion did not compare well. Using the microfabricated mixer, Km and kcat values of 75 +/- 13 microM and 44 +/- 3 s(-1) were determined. These values compare well to those obtained with the conventional stopped-flow apparatus for which Km was determined to be 60 +/- 6 microM and kcat was 47 +/- 4 s(-1). Enzyme inhibition assays with phenylethyl-beta-D-thiogalactoside (PETG) were also comparable. It was concluded that kinetically based, stopped-flow enzyme assays can be performed in 60 s or less with a miniaturized system of roughly 6 nL liquid volume when mixing is assisted with the described device.

Clinical Enzyme Tests↗

Matrix metalloproteinase in left ventricular remodeling and heart failure.

Accumulation of oxidized matrix between the endothelium and cardiac muscle, and endocardial endothelial dysfunction, are the hallmarks of congestive heart failure. The induction of oxidative stress, decrease in endothelial cell density, activation of matrix and disintegrin metalloproteinase, collagenolysis, and repression of cardiac inhibitor of metalloproteinase (CIMP) are associated with deposition of oxidized matrix. Studies that employ CIMP as genetic or proteomic therapeutic agent may improve the heart's response to nitric oxide donors. Identification of major players involved in the control of oxidative and proteolytic stresses that ameliorate matrix deposition by integrin shading will help to develop strategies to prevent congestive heart failure.

Clinical Enzyme Tests↗

Rapid enzymatic test for phenotypic HIV protease drug resistance.

A phenotypic resistance test based on recombinant expression of the active HIV protease in E. coli from patient blood samples was developed. The protease is purified in a rapid one-step procedure as active enzyme and tested for inhibition by five selected synthetic inhibitors (amprenavir, indinavir, nelfinavir, ritonavir, and saquinavir) used presently for chemotherapy of HIV-infected patients. The HPLC system used in a previous approach was replaced by a continuous fluorogenic assay suitable for high-throughput screening on microtiter plates. This reduces significantly the total assay time and allows the determination of inhibition constants (Ki). The Michaelis constant (Km) and the inhibition constant (Ki) of recombinant wild-type protease agree well with published data for cloned HIV protease. The enzymatic test was evaluated with recombinant HIV protease derived from eight HIV-positive patients scored from 'sensitive' to 'highly resistant' according to mutations detected by genotypic analysis. The measured Ki values correlate well with the genotypic resistance scores, but allow a higher degree of differentiation. The non-infectious assay enables a more rapid yet sensitive detection of HIV protease resistance than other phenotypic assays.

Clinical Enzyme Tests↗