Search PubMedSearch

PubMed · 3821295

A user-oriented validation method for clinical data.

Abstract

The patient data in hospitals is prone to many errors during computerization because of the large human element involved during the processes concerned. A user-oriented validation method, which has been found to be practical and acceptable, is suggested. A non-statistical approach is adopted in this regard. The qualitative requirements of all users for validation have been taken as the guidelines to achieve maximum user acceptability. A user-oriented data code sheet, whose format changes for different disease groups, has been devised to prevent most of the typographical errors. These code sheets have also been found to be of considerable help to doctors in keeping a check on any missed or incomplete investigations, examinations and history recording. The validation program detects all errors of a typographical nature and all commonly possible logical errors. In addition, the program outputs data values, whose accuracy is doubtful, in the form of warning messages like WARNED DATA and ERRONEOUS DATA. The data fields which do not contain any data are also output to help the clinicians to take note of investigations and clinical tests not done or whose results are awaited. The logical errors, if any, also help them in detecting and identifying atypical cases in any given disease group at the earliest possible stage of a patient's hospitalization. In this paper, the need for a user-oriented and non-statistical approach to the validation of clinical data has been discussed in detail and its advantages enumerated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N G Rao, B E Prasad, S K Guha, P G Reddy. A user-oriented validation method for clinical data.. https://doi.org/10.3109/14639238608997655

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Integration of a barcode reader with a commercial flow cytometer.

This report describes the application and installation of a barcode reader on a standard EPICS Elite flow cytometer. The barcode reader system eliminates keyboard entry of sample information on the cytometer. The system automates the transfer of sample information already present in our laboratory database to the cytometer at run time. The system uses a standard "off-the-shelf" bar code wand with a personal computer keyboard interface and requires no additional software at run time. No typing of sample information is required by the operator at any stage of normal sample operation at the cytometer. All operations are automatically coded into the cytometry software using the macro functions of the software. Tubes are inserted into the tube reader and sample information is transferred automatically into the cytometer. We have found that the system allows rapid and continuous operation of routine clinical and research samples. This automated data entry also reduces the possibility of data input errors.

Electronic Data Processing

Comparison of lymphocyte immunophenotypes obtained simultaneously from two different data acquisition and analysis systems on the same flow cytometer.

Immunophenotyping of different lymphocyte populations was carried out in parallel on 113 consecutively received specimens of human peripheral blood using 2 different data acquisition and analysis systems (EPICS C and 4Cyte-Acmecyte) on the same flow cytometer (EPICS C). The phenotypes analyzed were CD3+, CD4+, CD8+ CD56+ CD16+ CD3-, TCR-gamma delta+ CD8-, and TCR-gamma delta+ CD8+. Both HIV- and HIV+ specimens were used for this study, including some with CD4 levels as low as 2% of all lymphocytes. Despite differences in gating procedures and shapes of bitmap (rectilinear vs. "amorphous"), the 2 methods agreed to within 2% positive cells in 97% of the cases. Although some statistically significant biases in the methods were observed, these were small and not biologically important. We conclude that both methods of data acquisition and analysis, as employed by experienced operators on the EPICS C flow cytometer, gave essentially equivalent results for lymphocyte sub-populations in peripheral blood preparations.

Electronic Data Processing