Search PubMedSearch

PubMed · 3814733

Sample size for case-control studies using Cochran's statistic.

Abstract

Sample size determination for case-control studies of chronic disease are often based on the simple 2 X 2 tabular cross-classification of exposure and disease, thereby ignoring stratification which may be considered in the analysis. One consequence of this approach is that the sample size may be inadequate to attain a specified power and size when performing a statistical analysis on J 2 X 2 tables using Cochran's (1954, Biometrics 10, 417-451) statistic or the Mantel-Haenszel (1959, Journal of the National Cancer Institute 22, 719-748) statistic. A sample size formula is derived from Cochran's statistic and it is compared with the corresponding one derived when the data are treated as unstratified, and also with two other formulas proposed for stratified data analysis. The formula developed yields values slightly higher than one recently proposed by Muñoz and Rosner (1984, Biometrics 40, 995-1004), which assumes that both margins of each 2 X 2 table are fixed, while the present study considers only the case-control margin to be fixed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R F Woolson, J A Bean, P B Rojas. 1986. Sample size for case-control studies using Cochran's statistic.. https://pubmed.ncbi.nlm.nih.gov/3814733/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The influence of the spatial structure of focal hepatic lesions on volume measurements performed with two and three-dimensional sonography using the ellipsoid formula.

A total of 63 patients with localized hepatic lesions were examined using two and three-dimensional sonography. The tumor volumes were calculated by means of the ellipsoid formula, compared with an experimentally determined reference volume and subsequently differentiated into correct and erroneous measurements according to the WHO criteria for tumor volumes. In a second test series, an analysis of the tumor shapes was carried out using parallel projections. It could be seen that 65% of the erroneous measurements resulted from the use of the ellipsoid formula, a procedure which is used to determine the volume of hepatic lesions. In the third part of this study, it was found that findings which are difficult to measure are frequently not recognized as such by the investigator making use of two-dimensional sonography. As a consequence, the volume measurements of focal hepatic lesions in oncology patients being considered for particular therapies should preferably be carried out with the aid of planimetric measurements rather than with the use of the ellipsoid formula.

Biometry