Search PubMed⌕ Search

PubMed · 3804435

[Anthropometric parameters].

Abstract

Anthropometry is defined as the comparative measurement and study of the human body. Anthropometric measurements have been used for many years to assess the nutritional status of individuals and populations in the United States. More recently anthropometric measurements have become a routine part of the nutrition assessment of surgical patients. Upper arm anthropometry and handgrip dynamometry are rapid and inexpensive tests for detecting malnutrition, but they are not useful for preoperative screening to predict postoperative morbidity because appropriate standards are missing in Europe. In a prospective study none of these preoperatively measured variables were of predictive value to postoperative complications, relating the method to its specificity, sensitivity, and validity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

U Brenner, J M Müller, M Walter, W Holzmüller, H W Keller. 1986. [Anthropometric parameters].. https://pubmed.ncbi.nlm.nih.gov/3804435/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Differences between recumbent length and stature measurement in groups of 2- and 3-y-old children and its relevance for the use of European body mass index references.

OBJECTIVE: To compare length and stature measurements of young children and to examine the relevance of any difference for comparison with body mass index (BMI) references designed for use from birth to adulthood. SUBJECTS: A total of 426 2-y-old and 525 3-y-old children included in the Dortmund Nutritional and Anthropometrical Longitudinally Designed (DONALD) Study. DATA ANALYSIS: Length and stature were measured to the nearest millimetre using a stadiometre. Agreement between both measurements at age 2 and 3 y, respectively, was determined by mean differences and by comparison with the German BMI reference. RESULTS: The average length of 2-y-old girls and boys was 88.3 (3.1) and 89.9 (3.2) cm, mean differences (stature minus length) were -0.47 (0.65) and -0.45 (0.64) cm. The corresponding BMI values were 16.18 (1.3) and 16.46 (1.2) kg/m2, with mean differences of +0.17 (0.24) and +0.16 (0.23). According to stature, 9.4% of the girls and 10.8% of the boys were overweight (>90th percentile), while length classified 7.1 and 9.4% as overweight. Similar mean differences between length and stature were observed at age 3 y: -0.53 (0.62) and -0.47 (0.65) cm in height and +0.17 (0.20) and +0.14 (0.20) kg/m2 in the BMI of girls and boys, respectively. According to stature, 7.6 and 7.3% were overweight as opposed to 5.4 and 4.8% using length. The observed differences increased with higher BMI levels. CONCLUSION: Changing measurements from length to stature results in an upward shift of BMI, not reflected in current European BMI references. This small but systematic error may result in misinterpretation of individual BMI levels or trend observations.

Anthropometry↗

Development and assessment of the Canadian personal load carriage system using objective biomechanical measures.

The Defence Research and Development Canada--Toronto managed a collaborative team of designers, biomechanists, ergonomists and military stakeholders in the development of a new personal load carriage (LC) system for the Canadian Forces. Ergonomics design principles using objective measurement tools and user-centred feedback from soldiers were considered essential to system development. The purpose of this study was to provide a detailed report of contributions by biomechanical testing to the final design of the final Canadian LC system. The Load Carriage Simulator and Compliance Tester were used to test design iterations of: three fragmentation vests, seven tactical vests and three iterations of the backpack. Test data were compared to a data pool of seventeen previously tested systems. Results indicated that the objective measures helped the design team by: (1) quantifying and understanding the consequences of various design changes; (2) predicting soldiers' responses to design changes in skin contact pressure, force and relative motion; (3) objectively comparing design iterations to other systems; and (4) providing information quickly so that ideas and recommendations could be incorporated into the next design iteration. It was concluded that objective assessments added valuable information not easily interpreted from human trials. However, objective assessments cannot replace human trials for feedback on functionality and features.

Anthropometry↗

Early clinical results of the telemetric adjustable pulmonary artery banding FloWatch-PAB.

BACKGROUND: Adjustment of pulmonary artery banding (PAB) may be a challenging procedure in complex congenital heart defects. Whatever the technique used, subsequent re-operations are frequently needed to control the pulmonary blood flow or pressures. OBJECTIVE: To report the efficacy of a new telemetric adjustable PAB (FloWatch-PAB) operated with the help of an external control unit that transmits to the implant energy and commands to further narrow or release the pulmonary artery using radiofrequency waves. METHODS AND RESULTS: In a multicenter, prospective, nonrandomized, single-arm clinical investigation, 13 children (median age, 4.5 months; range, 6 days to 11 years; median weight, 4.2 kg; range, 3.1 to 27 kg) underwent implantation of the FloWatch-PAB through median sternotomy in 8 and left thoracotomy in 5. The diagnosis was multiple ventricular septal (VSD) defects with complex anatomy in 3, single ventricle without pulmonary stenosis in 2, VSD with elevated pulmonary vascular resistance (PVR) in 2, atrio-ventricular canal (AVC) with elevated pulmonary vascular resistance in 1, AVC with diminutive right ventricle in 1, complex transposition of the great arteries in 3, and pulmonary atresia with complex pulmonary arteries anatomy in 1. All patients had normosystemic systolic pulmonary artery pressure. Additional procedures were performed in 7: atrial septectomy in 2, double aortic arch division in 1, patent ductus arteriosus ligation in 2, and coarctation repair in 2. There were no early or late deaths or device-related complications in a mean follow-up of 24 weeks (range, 18 to 42 weeks). A mean of 5.8 telemetric regulations per patient using the FloWatch-PAB were required to adjust the tightening of the PAB to the clinical needs (narrowing 74%, releasing 26%). At last follow-up, systolic pulmonary artery pressure was within normal range in all patients but 1. Systemic oxygen saturation demonstrated optimal regulation of the pulmonary blood flow in all according to each specific defect. Four patients were successfully corrected (VSD closure, AVSD repair, and 2 arterial switches with VSD closure). The device was easily removed and the pulmonary artery re-expanded spontaneously. CONCLUSIONS: This new device is safe and allows optimal adjustment of PAB in complex heart defects. In children requiring PAB, the use of this technology can obviate the need for early re-operations and appears to be a valuable option in the panel of surgical alternatives for selected infants.

Anthropometry↗