A simple unconstrained dynamic knee simulator.

Abstract

The design of a simple dynamic knee simulator is described. In the simulator the joint dynamics are reproduced in-vitro in a knee specimen by controlling the time-histories of the tensions in two flexible cables acting as lumped muscle group equivalents, without constraining the natural conjunct and passive motions of the specimen. The two cable tensions acting individually are used to control the active flexion/extension motion, while their simultaneous action is used to control joint compressive force. The characteristics of the electrohydraulic servo system acting under real-time microprocessor control are described. The system performance during simulation of an idealized level-walking function is evaluated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O Szklar, A M Ahmed. 1987. A simple unconstrained dynamic knee simulator.. https://doi.org/10.1115/1.3138676

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A model to accumulate fractionated dose in a deforming organ.

PURPOSE: Measurements of internal organ motion have demonstrated that daily organ deformation exists throughout the course of radiation treatment. However, a method of constructing the resultant dose delivered to the organ volume remains a difficult challenge. In this study, a model to quantify internal organ motion and a method to construct a cumulative dose in a deforming organ are introduced. METHODS AND MATERIALS: A biomechanical model of an elastic body is used to quantify patient organ motion in the process of radiation therapy. Intertreatment displacements of volume elements in an organ of interest is calculated by applying an finite element method with boundary conditions, obtained from multiple daily computed tomography (CT) measurements. Therefore, by incorporating also the measurements of daily setup error, daily dose delivered to a deforming organ can be accumulated by tracking the position of volume elements in the organ. Furthermore, distribution of patient-specific organ motion is also predicted during the early phase of treatment delivery using the daily measurements, and the cumulative dose distribution in the organ can then be estimated. This dose distribution will be updated whenever a new measurement becomes available, and used to reoptimize the ongoing treatment. RESULTS: An integrated process to accumulate dosage in a daily deforming organ was implemented. In this process, intertreatment organ motion and setup error were systematically quantified, and incorporated in the calculation of the cumulative dose. An example of the rectal wall motion in a prostate treatment was applied to test the model. The displacements of volume elements in the rectal wall, as well as the resultant doses, were calculated. CONCLUSION: This study is intended to provide a systematic framework to incorporate daily patient-specific organ motion and setup error in the reconstruction of the cumulative dose distribution in an organ of interest. The realistic dose distribution in an organ of interest gives the true dose-volume relationship, and may play an important role in the evaluation of the dose response of human organs. Dose reconstruction during the course of treatment delivery can also be used as an important feedback for the online optimization of individual treatment plans.

Biomechanical Phenomena