On multiparameter data analysis in flow cytometry.

Abstract

Increasing numbers of parameters that are accessible to simultaneous measurement in flow cytometric instruments, combined with the extremely large sample sizes common in flow cytometry, make it necessary to examine methods of multivariate statistics for their applicability to problems of visualization and quantitative analysis of flow cytometric data. This article describes some approaches to dimensionality reduction that appear well suited for data sets obtained by flow cytometry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R C Mann. 1987. On multiparameter data analysis in flow cytometry.. https://doi.org/10.1002/cyto.990080211

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Heparin-like polymers modulate proinflammatory cytokine production by lipopolysaccharide-stimulated human monocytes.

The search for heparin-like materials remains an intensive field of research. In this context, we studied the immunomodulatory properties of semisynthetic dextran derivatives and naturally occurring sulfated polysaccharides present in brown seaweed (fucans). In this study, we investigated the functional potencies of fucan and dextran derivatives by analyzing their effects on the release of proinflammatory cytokines by resting or lipopolysaccharide (LPS)-stimulated human monocytes and their interactions on monocyte surfaces. The results showed that fucan, dextran derivatives, and heparin differentially (1) triggered interleukin-1alpha, tumor necrosis factor alpha, interleukin-6, and interleukin-8 production by monocytes in a dose-dependent manner, (2) modulated cytokine production by LPS-stimulated monocytes, and (3) specifically inhibited the binding of biotinylated LPS to monocyte membranes. Taken together, these data indicated that fucan and dextran derivatives displayed interesting immunomodulatory effects on human blood cells that could be relevant as new drugs or biomaterial coatings. Indeed, such polysaccharides, by regulating monocyte activation, could contribute to the improved biocompatibility of implants.

Flow Cytometry↗

Dissolution testing of a poorly soluble compound using the flow-through cell dissolution apparatus.

Dissolution of Pfizer Compound PD198306, a poorly soluble compound, was studied in 25 mM pH 9 sodium phosphate solution with 0.5% SLS using the flow-through cell dissolution apparatus. Unmicronized and micronized drug powders were tested. Several methods of loading the drug powder into the flow-through dissolution cells and their impact on dissolution were investigated. The influence of flow rate of the dissolution medium on the rate and extent of dissolution were studied. PD198306 has poor wettability even in the presence of 0.5% SLS. It was found that loading the drug powder into the dissolution cell in the form of a suspension provided the best dissolution profile in terms of the rate and extent of dissolution. The flow rate of 4 ml/min resulted in good particle size discrimination.

Flow Cytometry↗

Determination of individual cell Michaelis-Menten constants.

BACKGROUND: A novel methodology for the measurement and analysis of apparent K(M) (Michaelis-Menten constant) and V(MAX) values of individual cells is suggested. It is based on a mathematical model that considers substrate influx into the cell, its intracellular enzymatic hydrolysis, and the product efflux. The mathematical formulation was approximated linearly in order to analyze intracellular substrate conversion characteristics via Michaelis-Menten theory. METHODS: Utilizing static cytometry, the time dependence of the fluorescence intensity [FI(t)] emitted from prelocalized and defined FDA stained cells was recorded. This required frequent periodical measurements of the same cells, which are sequentially exposed to various fluorogenic substrate concentrations. RESULTS: Model simulations correlated with experimental results. Differences in distributions of individual K(M) and V(MAX) values of cells incubated with and without PHA were evident. Average K(M) and V(MAX) values of PHA-stimulated cells increased by 99% and 540%, respectively. CONCLUSIONS: This study may provide a tool for assessing intracellular enzymatic activity in individual intact cells under defined physiologic conditions. This may open new vistas in various areas, giving answers to critical questions arising in the field of cell and developmental biology, immunology, oncology, and pharmacology.

Flow Cytometry↗