Search PubMed⌕ Search

PubMed · 3529565

Quantitative sonography.

Abstract

The review presents a perspective on ultrasonic techniques which place numerical values on properties of tissue or physiological function. Two distinct approaches to tissue characterisation are identified and the various techniques employed are reviewed. The range of Doppler techniques currently in use or under development are described. The potential roles of the various techniques are discussed, using clinical results from the Ultrasonics Institute as a basis. Attenuation measurements show a considerable spread in results, but sound speed appears to correlate closely with the degree of fibrosis in liver and spleen. Other methods have been found useful in specialised areas. The use of pulsed Doppler with a resolution cell sufficiently large to encompass the entire vessel, in conjunction with B-mode imaging to determine geometry, permits volumetric flow measurements to be made in deep vessels and reveals previously inaccessible physiological data. The use of analysis techniques to provide quantitative information in the physiological state or function of tissue promises to add a new dimension to diagnostic ultrasound.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D E Robinson, R W Gill, G Kossoff. 1986. Quantitative sonography.. https://doi.org/10.1016/0301-5629(86)90099-2

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Doppler-free/Doppler-sliced ion imaging.

We demonstrate a hybrid Doppler-free/Doppler-sliced ion imaging approach that is well-suited for detection of H or D atoms. The method relies on 2 + 1 resonant ionization with identical, nearly counterpropagating beams that are coplanar but directed at a small angle relative to the detector face. This results in Doppler selection of the velocity component along the time of flight axis but Doppler-free detection in the plane perpendicular to this axis. The results show high signal level and excellent slicing ( approximately 5%), yielding velocity resolution completely determined by cation recoil in the ionization step.

Doppler Effect↗

Detection and correction of aliasing in ultrasonic measurement of blood flows with Ultrasonic-Measurement-Integrated simulation.

Detailed information of real blood flows is essential to develop an accurate diagnosis or treatment for serious circulatory diseases such as aortic aneurysms. Ultrasonic-Measurement-Integrated (UMI) simulation, in which feedback signals from the ultrasonic measurement make the simulation converge to the real blood flow, is a key to solving this problem. However, aliasing in the ultrasonic blood velocity measurement causes UMI simulation to converge to an erroneous result. In this paper, we have investigated the detection and the correction of aliasing in UMI simulation. The artificial force in the feedback of UMI simulation can be used as an index to detect the aliasing. We have proposed two ways for the correction of the aliasing. Correction A, in which measurement velocity is replaced with the computational one at the monitoring point where the aliasing is detected, substantially improves the accuracy of UMI simulation. Correction B, in which measurement velocity is replaced with an estimated Doppler velocity, can provide exactly the same result as that of UMI simulation using the nonaliased standard solution. Although correction B gives the most accurate result, correction A seems more robust and, therefore, a beneficial choice considering the other artifacts in the measurement.

Doppler Effect↗