Search PubMedSearch

PubMed · 3512240

Sodium.

Abstract

Although the clinical manifestations of an abnormal serum sodium concentration are uncommon, imbalances in sodium and water occur frequently. The major indications for the determination of the serum sodium are those situations in which the signs and symptoms of hyponatremia or hypernatremia are likely. In other situations, unless the determination of the sodium concentration will change the clinical management of the underlying disorder, the serum sodium is not very useful, and consequently, should not be ordered as a routine test. Laboratory tests should primarily be used to confirm clinical suspicions. The majority of disorders in which imbalances in sodium and water occur can be diagnosed on clinical grounds, irrespective of the serum sodium concentration.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T Janz. 1986. Sodium.. https://pubmed.ncbi.nlm.nih.gov/3512240/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Correction approaches for doubly labeled water in situations of changing background water abundance.

Doubly labeled water (DLW) is an accurate, portable method for measuring free-living energy expenditure. However, under certain conditions shifts in baseline abundance of deuterium and oxygen-18 tracers used in the method may produce errors in derivation of both turnover (k) rates and calculated energy expenditure. Present objectives were to examine during what experimental situations baseline errors arise and to address means of correcting for such baseline shifts so that consequent errors in energy expenditure calculations are minimized. Under conditions where shifts in baseline abundance for deuterium and oxygen-18 parallel abundances corresponding to the natural meteoric water ratio, self-compensating changes in k values for both deuterium and oxygen will result in minimal error to the DLW energy expenditure calculations, provided that the dose ratio of isotopes also mimics the meteoric water line. However, in situations where relative shifts in abundance of each isotope across the measurement period are not in parallel relative to the natural meteoric water line, then the potential for larger DLW errors exists. Optimally, subjects should equilibrate with the new water source. Failing this, correction for shifting baseline can be accomplished by measuring isotopic abundance changes in a control group of subjects not given the DLW dose, but performing similar tasks and consuming the same diet as the group given DLW. Alternatively, theoretically based correction values can be calculated given knowledge of the abundances of the final drinking water and the interval time that subjects consumed the new fluid.

Body Water

Effect of tissue heterogeneity on quantification in positron emission tomography.

As a result of the limited spatial resolution of positron emission tomographic scanners, the measurements of physiological parameters are compromised by tissue heterogeneity. The effect of tissue heterogeneity on a number of parameters was studied by simulation and an analytical method. Five common tracer models were assessed. The input and tissue response functions were assumed to be free from noise and systematic errors. The kinetic model was assumed to be perfect. Two components with different kinetics were mixed in different proportions and contrast with respect to the model parameters. Different experimental protocols were investigated. Of three methods investigated for the measurement of cerebral blood flow (CBF) (steady state, dynamic, integral), the second one was least sensitive to errors caused by tissue heterogeneity and the main effect was an underestimation of the distribution volume. With the steady state method, errors in oxygen extraction fraction caused by tissue heterogeneity were always found to be less than the corresponding errors in CBF. For myocardial blood flow the steady state method was found to perform better than the bolus method. The net accumulation of substrate (i.e. rCMRglc in the case of glucose analogs) was found to be comparatively insensitive to tissue heterogeneity. Individual rate constants such as k2 and k3 for efflux and metabolism of the substrate in the pool of unmetabolized substrate in the tissue, respectively, were found to be more sensitive. In studies of radioligand binding, using only tracer doses, the effect of tissue heterogeneity on the parameter kon.Bmax could be considerable. In studies of radioligand binding using a protocol with two experiments, one with high and one with low specific activity, Bmax was found to be insensitive while Kd was very sensitive to tissue heterogeneity.

Body Water