Search PubMedSearch

PubMed · 3473209

Method for passing interosseous wires.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Fujii. 1987. Method for passing interosseous wires.. https://doi.org/10.1016/s0278-2391(87)80024-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparative mechanical properties of spinal cable and wire fixation systems.

STUDY DESIGN: Surgical spinal cable and wire fixation systems were tested mechanically using standardized methodologies. OBJECTIVES: To compare the relative mechanical properties and biomechanical performances of the different commercially available spinal wire and cable fixation devices, and to provide information that will help in selecting different cables for different clinical applications. SUMMARY OF BACKGROUND DATA: Spinal cables have become extensively used for spinal fixation; however, there are few published accounts delineating their mechanical properties. No reports have compared the relative properties of different cable systems. METHODS: Nine spinal cable and wire fixation systems were mechanically tested to compare their static tensile strength, stiffness, fatigue strength, creep, conformance, and abrasion properties. Titanium and stainless steel Codman cable, Danek cable, and AcroMed cable, polyethylene Smith & Nephew cable, and 20- and 22-gauge stainless steel monofilament Ethicon wire were tested using identical methodologies. The cable or wire was connected into loops with methods that simulated in vivo clinical applications. RESULTS: Under static tensile testing, titanium cables had 70% to 90% of the ultimate tensile strength of the comparable steel cables; the different cables were 100% to 600% stronger than monofilament wire; the ultimate strength of the polyethylene cable was similar to that of the strongest available steel cable. Fatigue testing delineated important differences among the different materials. For a given manufacturer, titanium cables were always more susceptible to fatigue than stainless steel cables of comparable diameter. Polyethylene cable withstood cyclical loading without breaking better than all of the metal cables and wires. The mechanisms of failure differed substantially among materials and types of tests. Polyethylene cables exhibited significant stretching or "creep" at loads that were much lower than the static failure loads. In contrast, no wire cable demonstrated creep. Monofilament wires demonstrated little creep. Polyethylene cables failed by elongating and loosening; wire cables failed by breaking. Monofilament wire and cables conformed least to a solid surface; polyethylene cable conformed the most and flattened out against solid surfaces. Abrasion properties depended on the surface characteristics of the implants. Polyethylene cable was abraded by (and eventually failed by wearing against) the simulated bone, a result that did not occur with any metal cables or wires. The steel and titanium cables and the monofilament wires all had an ability to abrade through simulated bone. CONCLUSIONS: Titanium, steel, and polyethylene cable systems all behave substantially differently mechanically compared with monofilament wire. The relative advantages and disadvantages of each particular products should be considered when selecting an implant for a specific clinical use.

Bone Wires

Suspended circummandibular wire fixation for mixed-dentition pediatric mandible fractures.

OBJECTIVE: To introduce and evaluate the technique of cirummandibular wires with piriform rim suspension (CMW-PRS) combined with arch bars and a fracture site bridle in the treatment of mixed-dentition pediatric mandible fractures. DESIGN: Five male patients (mean age, 8.2 years [age range, 7-10 years]) with an isolated mixed-dentition mandible fracture were treated with the CMW-PRS technique at the University of Texas Health Science Center, San Antonio, from 1985 to 1987 and at the University of Missouri, Columbia, from 1992 to 1995. Clinical and radiographic fracture healing, somatosensory status, and complications were evaluated. RESULTS: All patients demonstrated clinical union to their preinjury occlusion by 3 or 4 weeks. They remained without complications until they were no longer available for follow-up. Panoramic radiographs supported the findings of clinical examinations throughout the study, and no radiographic abnormalities were found. There were no somatosensory disturbances of the lingual or mental/inferior alveolar nerves. One patient required a tracheostomy unrelated to the procedure. CONCLUSION: The CMW-PRS technique combined with arch bars and a fracture site bridle wire achieved equivalent historical results when compared with the dental splint. The potential advantages and disadvantages of the CMW-PRS technique compared with those of monocortical bone plating, as well as the significant advantages of the CMW-PRS over the dental splint, are discussed in the text.

Bone Wires

Use of a cast spreader during reoperative sternotomy.

We report a modified use for an old tool: separation of the sternal edges during repeat sternotomy with a cast spreader. We have found that this technique improves our exposure, causes no trauma to bone, and minimizes the risk of damage to underlying mediastinal structures.

Bone Wires