Search PubMed⌕ Search

PubMed · 3465699

Methyl acrylate.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1986. Methyl acrylate.. https://pubmed.ncbi.nlm.nih.gov/3465699/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Responsive and recognitive hydrogels using star polymers.

Polymeric networks that have inherent capabilities to recognize different molecules and chemical changes in their environment are the next generation of materials that will aid in the diagnosis and treatment of diseases. We have prepared new networks based on star polymers that were designed to be responsive and recognitive. Using molecular imprinting with D-glucose and crosslinking with poly(ethylene glycol) dimethacrylate with an ethylene glycol chain of nominal molecular weight 600, we prepared star polymer networks, which exhibited over 300% more uptake for D-glucose compared to D-fructose. Using copolymerization with methacrylic acid, we prepared star polymer networks with pH-sensitivity, which showed a sharp transition in swelling around a pH of 4.5.

Acrylates↗

Biocompatibility of chemoenzymatically derived dextran-acrylate hydrogels.

The biocompatibility of chemoenzymatically generated dextran-acrylate hydrogels has been evaluated in vitro, using human foreskin fibroblasts, and in vivo, by subcutaneous and intramuscular implantation in Wistar rats for up to 40 days. In vitro tests show that hydrogel extracts only minimally reduced (<10%) the mitochondrial metabolic activity of fibroblasts. Direct contact of the hydrogels with cells induced a cellular proliferation inhibition index (CPII) of 50-80%, compared with a control, whereas through indirect contact, the CPII values were <16%, suggesting that the high CPII values achieved in the direct assay test were likely due to mechanical stress or limitations in oxygen diffusion. Hence, the hydrogels were noncytotoxic. Moreover, cell-material interaction studies show that these hydrogels were nonadhesive. Finally, histologic evaluation of tissue response to subcutaneous and intramuscular implants showed acceptable levels of biocompatibility, as characterized by a normal cellular response and the absence of necrosis of the surrounding tissues of the implant. In the first 10 days, the foreign-body reaction in the intramuscular implantation was more severe than in subcutaneous implantation, becoming identical after 30 days. In both cases, dextran hydrogels did not show signs of degradation 6 weeks postimplantation and were surrounded by a thin fibrous capsule and some macrophages and giant cells. This response is typical with a number of nondegradable biocompatible materials. These results indicate that dextran hydrogels are biocompatible, and may have suitable applications as implantable long-term peptide/protein delivery systems or scaffolds for tissue engineering.

Acrylates↗

Experimental study of albumin and lysozyme adsorption onto acrylic acid (AA) and 2-hydroxyethyl methacrylate (HEMA) surfaces.

Many commercial soft contact lenses are based on poly-2-hydroxyethyl methacrylate (HEMA) and acrylic acid (AA) hydrogels. The adsorption of proteins, albumin and lysozyme, on such contact lens surfaces may cause problems in their applications. In this work the adsorption of proteins, albumin and lysozyme, on hydrogel surfaces, AA and HEMA, was investigated as a function of concentration of protein. Also the effects of pH and ionic strength of protein solution on the adsorption of protein were examined. The obtained results indicated that the degree of adsorption of protein increased with the concentration of protein, and the adsorption of albumin on HEMA surface at the studied pHs (6.2-8.6) was higher than AA surface, whereas the adsorption of lysozyme on AA surface at the same pHs was higher than HEMA. The change in ionic strength of protein solution affected the proteins adsorption on both AA and HEMA surfaces. Also, the amount of sodium ions deposited on the AA surface was much higher than HEMA surface. This effect can be related to the negative surface charge of AA and its higher tendency for adsorption of sodium ions compared to the HEMA surface.

Acrylates↗