Search PubMedSearch

PubMed · 3353714

Multiplex DNA sequencing.

Abstract

The increasing demand for DNA sequences can be met by replacement of each DNA sample in a device with a mixture of N samples so that the normal throughput is increased by a factor of N. Such a method is described. In order to separate the sequence information at the end of the processing, the DNA molecules of interest are ligated to a set of oligonucleotide "tags" at the beginning. The tagged DNA molecules are pooled, amplified, and chemically fragmented in 96-well plates. The resulting reaction products are fractionated by size on sequencing gels and transferred to nylon membranes. These membranes are then probed as many times as there are types of tags in the original pools, producing, in each cycle of probing, autoradiographs similar to those from standard DNA sequencing methods. Thus, each reaction and gel yields a quantity of data equivalent to that obtained from conventional reactions and gels multiplied by the number of probes used. To date, even after 50 successive probings, the original signal strength and the image quality are retained, an indication that the upper limit for the number of reprobings may be considerably higher.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G M Church, S Kieffer-Higgins. 1988-04-08. Multiplex DNA sequencing.. https://doi.org/10.1126/science.3353714

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Oligonucleotide labeling methods. 3. Direct labeling of oligonucleotides employing a novel, non-nucleosidic, 2-aminobutyl-1,3-propanediol backbone.

Novel CE-phosphoramidite (7a-e) and CPG (8a, c, d, e) reagents have been prepared from a unique 2-aminobutyl-1,3-propanediol backbone. The reagents have been used to directly label oligonucleotides with fluorescein, acridine, and biotin via automated DNA synthesis. The versatile 2-aminobutyl-1,3-propanediol backbone allows for labeling at any position (5', internal, and 3') during solid phase oligonucleotide synthesis. Multiple labels can be achieved by repetitive coupling cycles. Furthermore, the 3-carbon atom internucleotide phosphate distance is retained when inserted internally. Using this method, individual oligonucleotides possessing two and three different reporter molecules have been prepared.

Automation

[Routine application of HLA class II oligotyping. Value of automatization].

HLA class II typing by DNA amplification and hybridization with allele-specific oligonucleotides has led to an improvement of the overall typing accuracy. In an attempt to apply this procedure to a large-scale analysis, we sought to implement an automation system using the Biomek 1,000 robotic work-station. This system allows a rapid preparation of many consecutive samples and avoids the risk of human errors. It is now routinely used in several laboratories.

Automation