Search PubMed⌕ Search

PubMed · 3310726

[Anesthesia systems].

Abstract

A clear understanding of technical details is essential for safe handling of anesthetic machines. Following the ideas of E.A. Ernst, it is suggested that anesthesia systems be differentiated according to the underlying principles of construction into rebreathing systems, flow- and valve-controlled non-rebreathing systems, and systems without reservoirs. This classification seems much clearer than the usual differentiation into closed, semiclosed, semiopen, and open systems, which is based upon functional criteria. Anesthesia systems must be understood as technical parts (hardware) of anesthetic machines with variable function according to the chosen fresh gas flow (software). An unequivocal characterization of an anesthetic system will only be possible if its technical properties are described together with the fresh gas flow used. Most anesthetic machines currently in use are equipped with a circle system and sophisticated monitoring, which is designed for the rebreathing technique. This technique can only be used advantageously, however, if the rebreathing system is used in conjunction with substantially reduced fresh gas flows.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Baum. 1987. [Anesthesia systems].. https://searchpubmed.org/record/pubmed%3A3310726/anesthesia-systems

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Perception of training needs and opportunities in advanced airway skills: a survey of British and Irish trainees.

BACKGROUND AND OBJECTIVE: We surveyed delegates at the Group of Anaesthetists in Training (UK) meeting to investigate evidence of a training-gap (number of fibreoptic intubations believed to bestow competence vs. number actually performed). METHODS: Questionnaires were distributed to and collected from delegates in person. Questions covered six areas, including experience of fibreoptic intubation and cricothyrotomy, fibreoptic intubation as a specialist skill and ethical issues. RESULTS: We received 221 replies (76%). All trainees believed competence to be achievable with 10 intubations (interquartile range (IQR) 10-20); the median number performed was 2 (IQR 0-4). This was statistically significant for the groups' senior house officers, 1st and 2nd year registrars and 3rd and 4th year registrars; P < 0.0001. Many final year trainees (12/20, 60%) also failed to achieve their competency target. Few trainees had seen or performed any cricothyrotomies (medians 0, IQRs 0-1 and 0-0). Most (195/208, 94%) believed that fibreoptic intubation was a core skill and 199/212 (94%) believed that all should be competent by completion of training. Ten percent (n = 208) felt it unethical to perform an awake training intubation with full consent and 10% believed it acceptable without explanation. Most (82.7%) would fibreoptically intubate an asleep patient (requiring intubation) without consent. CONCLUSION: Trainees reported a gap between their perception of competence and achievement in awake fibreoptic intubation. Simple and complex simulations and structured training programmes may help. Anaesthetists must address the ethics of clinical training in advanced airway management.

Anesthesiology↗