Search PubMed⌕ Search

PubMed · 3249669

Accommodation and apparent distance.

Abstract

The ability to judge egocentric distance was assessed in sixteen normal observers under conditions where monocular blur-driven accommodation provided the only source of information regarding changes in target dioptric distance. Accommodation and apparent distance were measured over an optical range of 2 to 6 D for each of three targets which differed in their effectiveness as accommodative stimuli (excellent, moderate, and poor). For the excellent and moderate accommodative targets, apparent distance decreased as accommodation increased, with both targets sharing a common linear function. Apparent distance, however, tended to exceed accommodative distance and was relatively compressed in scale. As expected, accommodative response and apparent distance diminished in range as target effectiveness was reduced. The poor accommodative target represented the limiting case wherein accommodation failed to deviate from the tonic level, and apparent distance remained constant. There were considerable intersubject differences in the ability to judge distances on the basis of accommodation. The results indicate that accommodation can indeed serve as a source of distance information, particularly for some individuals.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S K Fisher, K J Ciuffreda. 1988. Accommodation and apparent distance.. https://doi.org/10.1068/p170609

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Three-dimensional ultrasound biomicroscopic examinations for haptic differentiation of potentially accommodative intraocular lenses].

PURPOSE: The principal ability of potentially accommodative IOLs is based on an axial shift of the IOL optics induced by the ciliary body action in interaction with a reversible change in haptic angulation. The aim of this study was to investigate the accommodative performance of this new IOL generation. METHOD: The authors have designed a test device to study IOL performance experimentally. These results were extrapolated to the in vivo situation in patients with accommodative implants. RESULTS: The 3D high-resolution presentation of the anterior segment of the eye allows a separation of the IOL haptic elements. In vitro and in the selected in vivo cases a change in haptic angulation <10 degrees in combination with a maximal IOL shift of 0.5 mm was found. CONCLUSIONS: The simulation model used in combination with 3D ultrasound biomicroscopy provides information about the potential of accommodative IOL designs. Conclusions corresponding to changes in haptic angulation during accommodation can be drawn and applied to the in vivo situation.

Accommodation, Ocular↗

Triple-A syndrome with prominent ophthalmic features and a novel mutation in the AAAS gene: a case report.

BACKGROUND: Triple-A syndrome (Allgrove syndrome) is an autosomal recessive disorder characterized by adrenal insufficiency, alacrima, achalasia, and - occasionally - autonomic instability. Mutations have been found in the AAAS gene on 12q13. CASE PRESENTATION: We present the case of a 12 year-old boy with classic systemic features of triple-A syndrome and several prominent ophthalmic features, including: accommodative spasm, dry eye, superficial punctate keratopathy, and pupillary hypersensitivity to dilute pilocarpine. MRI showed small lacrimal glands bilaterally. DNA sequencing of PCR-amplified fragments from the 16 exons of the AAAS gene revealed compound heterozygosity for a new, out-of-frame 5-bp deletion in exon 15, c1368-1372delGCTCA, and a previously-described nonsense mutation in exon 9, c938C>T, R286X. CONCLUSIONS: In addition to known ophthalmic manifestations, triple-A syndrome can present with accommodative dysregulation and ocular signs of autonomic dysfunction.

Accommodation, Ocular↗

Spatially variant changes in lens power during ocular accommodation in a rhesus monkey eye.

This study investigated the changes in ocular aberrations that occur over the entire lens equatorial diameter during accommodation in iridectomized rhesus monkey eyes to understand the nature of accommodative lenticular deformation. Accommodation was centrally stimulated to a range of different response amplitudes (0 D to approximately 11 D), and ocular aberrations were measured with a Shack-Hartmann wavefront sensor in both eyes of one previously iridectomized 10-year-old rhesus monkey. At the highest amplitude in the two eyes, aberrations were analyzed over entrance pupil diameters ranging from 3 to 8 mm in steps of 1 mm. Root mean square error of the total measured aberrations, excluding defocus, increased systematically with increasing accommodation from about 1 to 3.5 microns. Spherical aberration became systematically more negative, and vertical coma increased significantly in magnitude with accommodation. There was a strong accommodative change in power near the center of the lens and little change in power at the periphery. At the highest accommodative state, decreasing the analyzed entrance pupil diameter from 8 to 3 mm considerably reduced the wavefront error. The greater increase in optical power near the central region of the lens, combined with an accommodative pupillary miosis, would serve to maximize accommodative refractive change while maintaining acceptable image quality.

Accommodation, Ocular↗