Search PubMedSearch

PubMed · 3237022

[Electrosleep].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E M Orekhova. 1988. [Electrosleep].. https://pubmed.ncbi.nlm.nih.gov/3237022/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A dry electrode for EEG recording.

This paper describes the design, fabrication and testing of a prototype dry surface electrode for EEG signal recording. The new dry electrode has the advantages of no need for skin preparation or conductive paste, potential for reduced sensitivity to motion artifacts and an enhanced signal-to-noise ratio. The electrode's sensing element is a 3 mm stainless steel disk which has a 2000 A (200 nm) thick nitride coating deposited onto one side. The back side of the disk is attached to an impedance converting amplifier. The prototype electrode was mounted on a copper plate attached to the scalp by a Velcro strap. The performance of this prototype dry electrode was compared to commercially available wet electrodes in 3 areas of electroencephalogram (EEG) recording: (1) spontaneous EEG, (2) sensory evoked potentials, and (3) cognitive evoked potentials. In addition to the raw EEG, the power spectra of the signals from both types of electrodes were also recorded. The results suggest that the dry electrode performs comparably to conventional electrodes for all types of EEG signal analysis. This new electrode may be useful for the production of high resolution surface maps of brain activity where a large number of electrodes or prolonged recording times are required.

Electrodes

Effect of aging the hollow cathode by sputtering on the analytical precision of the hollow cathode discharge emission source.

Sputtering changes the analytical performance of the hollow cathode as an emission source. Proper conditioning (aging) of the hollow with sputtering greatly improves precision. Conditioning decreases the blank emission signal and changes the shape of the hollow. Micrographs which show the evolution of the bottom of the hollow into a stable bulb shape are presented. The blank emission signal decreases with aging of the hollow and approaches a constant value when the hollow is properly conditioned. A short-term stability (n = 5) of approximately 1.8% RSD has been observed frequently. An average long-term stability over several days (n = 45) of 4.5% for Li and 3.5% for Na in the emission signal from microsamples (less than 50 nL) deposited in the hollow cathode discharge source is reported here. Instrumentation, operation, and sample preparation procedures are described.

Electrodes