Search PubMedSearch

PubMed · 3225831

Technical note: electrosurgery active lead failures.

Abstract

A cause of electrosurgical burns in surgical procedures is faulty active leads. A survey of faults and modes of failures are reported. The design of a meter is given for use by a sterilizing department to enable leads to be checked. Using the criterion of two times the original resistance, 35 cables were found to be defective out of a population of about 200 cables. About half of these cables transmitted radio frequency (RF) power inefficiently: often power was intermittent and hot spots would develop. The commonest mode of failure was a break between the socket and the wire at the forceps end. Rejection criteria are reviewed and we suggest a resistance less than 0.3 omega.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S R Docker, R Railton, M Nieman. Technical note: electrosurgery active lead failures.. https://doi.org/10.3109/03091908809012411

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Inactivation of the peptide-sensitive channel from the yeast mitochondrial outer membrane: properties, sensitivity to trypsin and modulation by a basic peptide.

The yeast Peptide Sensitive Channel (PSC), a cationic channel of the mitochondrial outer membrane closes with slow kinetics at potentials of either polarity. The properties of this inactivation closely resemble those of the Voltage-Dependent Anion Channel (VDAC) slow kinetics closures. Addition of trypsin to one compartment suppresses the inactivation observed when this compartment is made positive, but does not affect the inactivation observed at potentials of reverse polarity. Both sides of the channel are sensitive. The reduced form of the Mast Cell Degranulating peptide (rMCD) increases the rate of inactivation, but only when the polarity of the compartment to which it is added is positive. The effect is not reversed by washing the peptide out, but is suppressed by trypsin. The peptide can bind to both sides of the membrane. The effect of rMCD on PSC closely resembles that of the "modulator" on VDAC. The similarities between PSC and VDAC suggest that the former might be a cationic porin of the mitochondrial outer membrane possessing a structure closely related to that of VDAC.

Electric Conductivity

Channel formation by a neurotoxic prion protein fragment.

Prions cause neurodegenerative disease in animals and humans. Recently it was shown that a 21-residue fragment of the prion protein (106-126) could be toxic to cultured neurons. We report here that this peptide forms ion-permeable channels in planar lipid bilayer membranes. These channels are freely permeable to common physiological ions, and their formation is significantly enhanced by "aging" and/or low pH. We suggest that channel formation is the cytotoxic mechanism of action of amyloidogenic peptides found in prion-related encephalopathies and other amyloidoses. The channels reported here are large enough and nonselective enough to mediate cell death through discharge of cellular membrane potential, changes in ionic homeostasis, and specifically, influx of calcium, perhaps triggering apoptosis.

Electric Conductivity

In vitro evaluation of wire integrity and ability to reprocess single-use sphincterotomes.

BACKGROUND: Sphincterotomes are currently marketed as one-time-use items and constitute considerable cumulative expense in a busy endoscopy unit. It is uncertain whether these accessories can be safely reprocessed without loss of form and function. METHODS: We studied disposable sphincterotomes (five 5F, five 6F) in vitro as to their durability, electrical integrity, and ability to be adequately cleaned both manually and with ethylene oxide after contamination with 10(5) to 10(6) Mycobacterium chelonei. RESULTS: Seven of the 10 sphincterotomes withstood the rigors of reuse; three 6F sphincterotomes developed wire fracture between four and eight uses. Electrical integrity, as measured by an electrosurgical analyzer, remained intact up to time of breakage in all sphincterotomes. Manual cleaning followed by glutaraldehyde soak resulted in residual mycobacterial colonies in five 6F sphincterotomes and a single 5F sphincterotome. No instrument had residual organisms cultured following manual cleaning and ethylene oxide sterilization. CONCLUSIONS: The authors conclude that one-time-use sphincterotomes have the potential for safe reuse.

Electric Conductivity