C18 solid-phase isolation and high-performance liquid chromatography/ultraviolet diode array determination of fully methoxylated flavones in citrus juices.

Abstract

A new analytical methodology for the determination of fully methoxylated flavones (FMFs) in citrus juices is described. Isolation of the FMFs is carried out by percolation of 30 mL of clarified citrus juice (to which tetramethyl-o-kaempferol is previously added as internal standard) through a C18 Sep-Pak cartridge, washing with 3 mL of water followed by 5 mL of water/acetonitrile (3:1), and selective elution of the retained FMFs with 5 mL of water/acetonitrile (9:11). Determination of the isolated FMFs is carried out by reversed-phase high-performance liquid chromatography (HPLC) and UV diode array detection (DAD). Signals at wavelengths 320, 335, and 345 nm (bandwidth 4 nm) are simultaneously acquired, stored, plotted, and integrated. The column used is a microbore (200 x 2.1-mm) Hypersil ODS 5 microns. Elution is in gradient mode, using a ternary mobile phase (water/acetonitrile/tetrahydrofuran). Column temperature is 40 degrees C. Recovery yields are nearly 100% for all the FMFs detected and identified: isosinensetin, hexamethyl-o-gossypetin, sinensetin, tetramethyl-o-isoscutellarein, hexamethyl-o-quercetagetin, nobiletin, tetramethyl-o-scutellarein, heptamethoxyflavone, and tangeretin. Chromatographic separation of the FMFs is extremely dependent upon the minor changes of the mobile phase composition and percentages, gradient rate, and temperature. The UV spectra (230 to 400 nm) of the FMFs obtained under chromatographic conditions are given. The FMFs relative response factors at 320, 335, and 345 nm and their concentrations in hand-squeezed and commercial concentrated orange and mandarin juices are tabulated. The FMF concentration differences found among samples are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J M Sendra, J L Navarro, L Izquierdo. 1988. C18 solid-phase isolation and high-performance liquid chromatography/ultraviolet diode array determination of fully methoxylated flavones in citrus juices.. https://doi.org/10.1093/chromsci%2F26.9.443

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Hyphenation of ion exchange high-performance liquid chromatography with Fourier transform infrared detection for the determination of sugars in nonalcoholic beverages.

Fourier transform infrared spectroscopy (FT-IR) is presented here as a molecular-specific detection system for high-performance liquid chromatography (HPLC) in an aqueous phase, focusing on the chromatographic separation of sugars in beverages. The separation was achieved with an isocratic HPLC setup using an ion exchange column (counterion, Ca2+). The FT-IR detection of the C-O bands in the mid-IR between 1000 and 1200 cm-1 was performed in real time with a 25 microns flow cell without elimination of the solvent. Characteristic FT-IR spectra of the common sugars sucrose, glucose, and fructose in concentrations of 1 mg/mL could be recorded during the separation. The calibration of these compounds in the 5-100 mg/mL range resulted in a linear correlation with a standard deviation of the method (Sx0) of 0.11, 0.07, and 0.11 mg/mL for sucrose, glucose, and fructose, respectively. The method was, furthermore, applied to the analysis of nine soft drinks and fruit juices containing between 6 and 97 mg/mL of each carbohydrate. The accuracy of the method was confirmed by standard ion exchange HPLC with refractive index detection. The average deviation from the reference method was in the range of 0.5-0.9 mg/mL. Furthermore, the method was found to be suitable to identify and quantify also minor components in beverages, such as taurine (4 mg/mL) and ethanol (0.4 mg/mL).

Beverages