Search PubMedSearch

PubMed · 321278

Processing complete dentures.

Abstract

The processing of acrylic resin dentures is an exacting art but is relatively simple to carry out to perfection day after day, even when several dentures are processed at the same time. Nine salient factors in the proper processing of acrylic resin dentures were sequentially listed. Unfortunately, a number of these technical procedures are frequently overlooked or shortcuts may be substituted. Herein lie the causes of some hitherto unexplained clinical failures attributed to the acrylic resin denture base material. The acrylic resin denture base materials have been and are currently the best plastic for making dentures. This material has many unique assets and few faults. Its fine properties are often overlooked by the dentist who has several edentulous patients experiencing problems with dentures he made for them. Sore spots, faulty occlusion, looseness, and even breakage are most likely due to inadequate mouth conditioning or poor impressions, incorrect jaw relations, or the dentist's failure to remount the dentures prior to insertion. We have sufficient knowledge and scientific evidence to realize that most, if not all, denture problems are caused by the dentist's technique or by dentist-patient relationship. These problems should not be attributed to the acrylic resin material nor to the hard-working, conscientious dental laboratory technician. I doubt that more than 2 per cent of all complete denture difficulties experienced by frustrated patients would be solved by the introduction and availability of a new perfect denture base material.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J B Woelfel. 1977. Processing complete dentures.. https://pubmed.ncbi.nlm.nih.gov/321278/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Different antigenic nature in apparently healthy women with high serum CA 125 levels compared with typical patients with ovarian cancer.

BACKGROUND: CA 125 is a representative ovarian cancer-associated antigen defined by monoclonal antibody OC125. Recently, monoclonal antibodies were produced (designated 130-22 and 145-9) that were reactive with CA 125 but bound to a separate epitope named CA 130. There was a close correlation between serum CA 125 and CA 130 values in most instances. However, among more than 8000 serum samples, 5 apparently normal women had high serum CA 125 values, despite having normal CA 130 values. In this study, the antigenic nature of these five women was investigated. METHODS: Using gel chromatography, the molecular masses of CA 125 and CA 130 were estimated that were found in the five women with false-positive CA 125 values. The sera were examined using double-determinant assays combining iodine-125-labeled OC125 or iodine-125-labeled 130-22 with OCI25-coated or 145-9-coated beads. RESULTS: The molecular masses of both CA 125 and CA 130 were estimated as greater than 1000 kilodaltons (KD); the CA 130 mass from one of the five women with an abnormal CA 125 level was approximately 200 KD using gel chromatography. Using the double-determinant assays that combined iodine-125-labeled OC125 or iodine-125-labeled 130-22 with OC125-coated or 145-9-coated beads, high radioactivity was found only in the homologous assay using iodine-125-labeled OC125 with OC125-coated beads. These results suggest that the antigenic nature of CA 125 found in apparently healthy women differs from that found in patients with ovarian cancer and that CA 130 epitopes are not present. CONCLUSIONS: Measurement of serum CA 130 concentrations may be useful for excluding women with falsely elevated CA 125 values.

Acrylic Resins

Chemical contrast in X-ray microscopy and spatially resolved XANES spectroscopy of organic specimens.

The scanning transmission x-ray microscope at the National Synchrotron Light Source has been used to record x-ray absorption near-edge structure (XANES) spectra from 0.01-square-micrometer regions of organic specimens. The spectral features observed reflect the molecular structure of the dominant absorbing atoms and provide the contrast mechanism for high-resolution imaging with chemical sensitivity. This technique was used with x-ray energies near the carbon K absorption edge to identify and map separate phases in various polymer blends and to map the DNA distribution in chromosomes with a spatial resolution of 55 nanometers.

Acrylic Resins