Osteomyelitis.

Abstract

The use of 111In-labelled granulocyte scintigraphy is recognized as a reliable method for detecting osteomyelitis and has similar sensitivity and significantly increased specificity compared to bone scintigraphy and 67Ga studies. Recent published work using pure granulocytes labelled with 111In tropolonate to detect osteomyelitis resulted in sensitivity of 100% and specificity of 92%. 99Tcm as an alternative granulocyte label offers advantages of convenience, lower radiation dose and higher image resolution. We have scanned 20 patients with suspected osteomyelitis using autologous granulocytes labelled with 99Tcm hexamethylpropyleneamineoxime (HMPAO), 12 of whom had prosthetic joints. The scan results were correlated with clinical, radiographic, microbiological and histological findings. Sensitivity was 100% and specificity was 93% which compares favourably with results obtained using 111In-labelled granulocytes. We believe that labelled granulocyte scintigraphy is a useful investigation in the diagnosis of osteomyelitis and that 99Tcm HMPAO appears to be at least as useful as 111In as the labelling agent.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M E Roddie, A M Peters, S Osman, H J Danpure, J P Lavender, R D Neirinckx. 1988. Osteomyelitis.. https://doi.org/10.1097/00006231-198810000-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Performance evaluation of the immature granulocyte parameter on the Sysmex XE-2100 automated hematology analyzer.

Recently, St. Anthony's Medical Center Laboratory (SAMC) in St. Louis, Missouri, installed a new automated hematology analyzer, the Sysmex XE-2100. The XE-2100 has an additional differential parameter, the immature granulocyte (IG) parameter. Prior to implementation, the IG parameter was evaluated by comparison to the manual immature granulocyte count. Immature granulocytes counted manually, as well as the automated count, included metamyelocytes, myelocytes, and promyelocytes. Manual differentials were performed on each specimen by 2 experienced medical technologists using the National Committee for Clinical Laboratory Standards (NCCLS) document H20-A. In addition to evaluating the IG parameter, St. Anthony's laboratory plans to report the automated IG count from the XE-2100, with or=5% and an absolute IG number of >or=0.5 x 103 will require differentiation by a manual differential count. An IG percentage <5% and an absolute IG number of <0.5 x 103 will not require differentiation by manual slide review. In this comparison of the IG count on the XE-2100 to the manual count, the correlation coefficient was 0.83. The XE-2100 IG results showed significant correlation with the results from the manual immature granulocyte count. We concluded that the XE-2100 IG demonstrated comparable performance to the manual IG count.

Granulocytes↗