Search PubMedSearch

PubMed · 3155355

Guidelines for determining threshold level for speech.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

1988. Guidelines for determining threshold level for speech.. https://pubmed.ncbi.nlm.nih.gov/3155355/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effects of hypothermia on cochlear micromechanical properties in humans.

The aim of the present experiment was to investigate the influence of hypothermia on transient evoked otoacoustic emissions (TEOAEs) in humans. Hypothermic alterations were brought about directly by cooling the cardiovascular system of young children during open heart bypass surgery. This condition caused TEOAE levels to decrease with a significant positive correlation between total and frequency band TEOAE amplitudes during cooling. TEOAEs were totally abolished at tympanic temperatures around 30 degrees C, without it being possible to find differences in TEOAE alteration among the frequency components. During rewarming, the changes reversed and TEOAEs returned to their initial prehypothermia status, although sometimes only partially. Despite large possible metabolic changes caused by this hypothermic condition at various levels, it is concluded that the motile properties of outer hair cells (OHCs), that are related to TEOAEs, are temperature-sensitive. The total suppression found in deep hypothermia (above 30 degrees C) could conceivably be attributable to a process involving a temperature-dependent energy source.

Auditory Threshold

The bone-anchored hearing aid: reference quantities and functional gain.

One of the most important parameters of a hearing aid is its gain characteristics. Under ideal circumstances, the gain and the functional gain (FG) are the same for an air conduction device. This is not the case, however, with bone conduction devices, e.g., the bone-anchored hearing aid (BAHA). In this article, the relation between the gain and the FG is derived for bone conduction devices including the BAHA. Reference quantities used when measuring bone conduction devices also are presented.

Auditory Threshold

The relation between gap detection, loudness, and loudness growth in noise-masked normal-hearing listeners.

Gap detection was measured for 50 and 1000-Hz-wide noise markers arithmetically centered on 1000 Hz. The markers were presented in a lowpass background noise having a high-frequency cutoff of 2000 Hz. The pressure spectrum level of the background noise was either 0 or 40 dB/Hz. Gap detection was determined at sensation levels (SLs) of 10, 15, 20, and 30 dB in the 0-dB/Hz background, and at SLs of 10, 15, and 20 dB in the 40-dB/Hz background. Because loudness increased more steeply in the higher level noise background, the markers in the 40-dB/Hz background were at higher loudness (and at a steeper portion of the loudness growth function) than markers in the 0-dB/Hz background, for markers matched in terms of SL. The main goal of the experiment was to determine whether gap detection would be relatively poor at steep portions of the loudness growth function due to the gap being confused with ongoing random dips. Such confusion might be particularly great when the noise bandwidth was narrow (and therefore characterized by prominent fluctuation) and the growth of loudness was steep. Gap detection was poorer for the 50-Hz-wide marker than for the 1000-Hz-wide marker. For a given marker bandwidth at a given SL, gap detection was similar whether the marker was presented in the 0-dB/Hz noise or the 40-dB/Hz noise. Supplementary conditions indicated that (1) gap detection results for 50-Hz-wide markers presented at equal SL's were also similar between a 0-dB/Hz noise background and a 55-dB/Hz noise background, and that (2) gap detection for 50- and 1000-Hz-wide markers was poorer in a 40-dB/Hz background than in a 0-dB/Hz background when markers were matched for loudness. The results generally indicated similar gap detection thresholds for markers presented at similar SLs across a relatively wide range of background noise levels. Gap detection was related more closely to the marker-to-noise ratio than to the loudness relation between markers or the steepness of loudness growth.

Auditory Threshold