Search PubMed⌕ Search

PubMed · 312375

An automatic over-range correcting circuit.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L W Korba, A J Cousin. 1979. An automatic over-range correcting circuit.. https://doi.org/10.1007/bf02440968

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Two-electrode biopotential amplifier with current-driven inputs.

A circuit was developed for a differential two-electrode biopotential amplifier. Current sources at the amplifier inputs were controlled by the common-mode voltage. This principle is well known in telephony for interfacing the telephone line with analogue-type phones. A low impedance of about 1 k(ohm) was obtained between each input and the common point of the circuit. The differential input impedance of 60 M(ohm) was obtained with the use of precision resistors. Considerable reduction in the common-mode voltages of more than 200 times resulted. The circuit can be useful for biosignal acquisition from subjects in areas of very high electromagnetic fields, where high common-mode voltages could saturate the input amplifier stages.

Amplifiers, Electronic↗

Frequency downconversion and phase noise in MIT.

High-frequency (3-30 MHz) operation of MIT systems offers advantages in terms of the larger induced signal amplitudes compared to systems operating in the low- or medium-frequency ranges. Signal distribution at HF, however, presents difficulties, in particular with isolation and phase stability. It is therefore valuable to translate received signals to a lower frequency range through heterodyne downconversion, a process in which relative signal amplitude and phase information is in theory retained. Measurement of signal amplitude and phase is also simplified at lower frequencies. The paper presents details of measurements on a direct phase measurement system utilizing heterodyne downconversion and compares the relative performance of three circuit configurations. The 100-sample average precision of a circuit suitable for use as a receiver within an MIT system was 0.008 degrees for input amplitude -21 dBV. As the input amplitude was reduced from -21 to -72 dBV variation in the measured phase offset was observed, with the offset varying by 1.8 degrees. The precision of the circuit deteriorated with decreasing input amplitude, but was found to provide a 100-sample average precision of <0.022 degrees down to an input amplitude of -60 dBV. The characteristics of phase noise within the system are discussed.

Amplifiers, Electronic↗

Noise in miniature microphones.

The internal noise spectrum in miniature electret microphones of the type used in the manufacture of hearing aids is measured. An analogous circuit model of the microphone is empirically fit to the measured data and used to determine the important sources of noise within the microphone. The dominant noise source is found to depend on the frequency. Below 40 Hz and above 9 kHz, the dominant source is electrical noise from the amplifier circuit needed to buffer the electrical signal from the microphone diaphragm. Between approximately 40 Hz and 1 kHz, the dominant source is thermal noise originating in the acoustic flow resistance of the small hole pierced in the diaphragm to equalize barometric pressure. Between approximately 1 kHz and 9 kHz, the noise originates in the acoustic flow resistances of sound entering the microphone and propagating to the diaphragm. To further reduce the microphone internal noise in the audio band requires attacking these sources. A prototype microphone having reduced acoustical noise is measured and discussed.

Amplifiers, Electronic↗