Search PubMed⌕ Search

PubMed · 3123065

Quantification in peripheral angiography.

Abstract

The purpose of this report is to review the wide variety of quantitative methods that either augment the angiogram or improve the evaluation of peripheral vascular disease when used in conjunction with the angiogram. The term "quantitative angiography" has many connotations in this area. On the one hand it may refer to any type of measurement of vessel diameter and luminal narrowing from angiographic images, or to an analysis of relative blood flow using videodensitometric methods. In the broader context it may mean any objective hemodynamic measurement that is obtained at the time of angiography, for example, pressure drop across a stenosis or blood flow studies using Doppler techniques. Lastly there are the indirect, noninvasive measurements that angiographers use, in conjunction with the patient history and clinical examination, to interpret the angiographic images. Doppler pressure measurements and plethysmography are two examples in wide clinical use. Magnetic resonance imaging (MRI) represents a noninvasive imaging modality that can concomitantly quantitate blood flow; however, its clinical utility in the evaluation of peripheral vascular disease is yet to be established.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D P Harrington, K Kandarpa. 1987. Quantification in peripheral angiography.. https://doi.org/10.1007/bf02577350

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simultaneous assessment of fractional and coronary flow reserves in cardiac transplant recipients: Physiologic Investigation for Transplant Arteriopathy (PITA Study).

BACKGROUND: The utility of measuring fractional flow reserve (FFR) to assess cardiac transplant arteriopathy has not been evaluated. Measuring coronary flow reserve (CFR) as well as FFR could add information about the microcirculation, but until recently, this has required two coronary wires. We evaluated a new method for simultaneously measuring FFR and CFR with a single wire to investigate transplant arteriopathy. METHODS AND RESULTS: In 53 cases of asymptomatic cardiac transplant recipients without angiographically significant coronary disease, FFR and thermodilution-derived CFR (CFRthermo) were measured simultaneously with the same coronary pressure wire in the left anterior descending artery and compared with volumetric intravascular ultrasound (IVUS) imaging. The average FFR was 0.88+/-0.07; in 75% of cases, the FFR was less than the normal threshold of 0.94; and in 15% of cases, the FFR was < or =0.80, the upper boundary of the gray zone of the ischemic threshold. There was a significant inverse correlation between FFR and IVUS-derived measures of plaque burden, including percent plaque volume (r=0.55, P<0.0001). The average CFRthermo was 2.5+/-1.2; in 47% of cases, CFRthermo was < or =2.0. In 14%, the FFR was normal (> or =0.94) and the CFR was abnormal (<2.0), suggesting predominant microcirculatory dysfunction. CONCLUSIONS: FFR correlates with IVUS findings and is abnormal in a significant proportion of asymptomatic cardiac transplant patients with normal angiograms. Simultaneous measurement of CFR with the same pressure wire, with the use of a novel coronary thermodilution technique, is feasible and adds information to the physiological evaluation of these patients.

Angiography↗

Collagenase plaque digestion for facilitating guide wire crossing in chronic total occlusions.

BACKGROUND: Chronic total occlusions (CTOs) are associated with significant angina, impaired left ventricular function, and worse long-term outcomes. Percutaneous coronary interventions in CTO are unsuccessful in up to 50% of cases, primarily because of inability to cross the lesion with a guide wire. Collagen is the predominant component of the atherosclerotic plaque. The objective of this study was to determine the efficacy and toxicity of local delivery of a collagen-degrading enzyme to facilitate guide wire crossing in CTO. METHODS AND RESULTS: Type IA collagenase (100 or 450 microg) or placebo was locally administered to 45 CTOs in a rabbit femoral artery model. Mean occlusion duration was 16+/-5 weeks. Attempts to cross the CTO (mean length, 28+/-9 mm) with conventional guide wires were assessed at 72 hours after treatment. An additional 3 arteries per group were assessed for collagenase effects at 24 hours after treatment. Successful guide wire crossings were significantly higher in collagenase-treated arteries (13 of 21, 62%) than in placebo-treated arteries (7 of 24, 29%) (P=0.028). No adverse effects on arterial structure were observed in collagenase-treated arteries. At 24 hours, collagenase-treated arteries demonstrated increased collagenase protein, gelatinase activity, and collagen fragments. CONCLUSIONS: Local delivery of collagenase can safely facilitate guide wire crossing of CTO. This novel approach could lead to higher percutaneous coronary intervention success rates in CTO.

Angiography↗

Principles and applications of balanced SSFP techniques.

During the past 5 years balanced steady-state free precession (SSFP) has become increasingly important for diagnostic and functional imaging. Balanced SSFP is characterized by two unique features: it offers a very high signal-to noise ratio and a T2/T1-weighted image contrast. This article focuses on the physical principles, on the signal formation, and on the resulting properties of balanced SSFP. Mechanisms for contrast modification, recent clinical application, and potential extensions of this technique are discussed.

Angiography↗