Interface between titanium 6,4 alloy implants and bone.

Abstract

This paper presents the results of animal studies on the interface between 6 aluminum, 4 vanadium, titanium alloy and bone. 7 New Zealand white rabbits were anaesthetised and a new design of threaded implant inserted into the tibial metaphysis of each leg. 3 further animals had fine lathe turnings inserted in the same site. The animals were sacrificed 7 weeks later and the implants removed together with the surrounding bone. After suitable processing of the specimens, they were subjected to scanning and transmission electron microscope studies. Compact bone was found in close proximity to the surface of the metal. With higher magnifications, the bone was found to be in intimate contact with the metal. There was no suggestion of the presence of cells or uncalcified collagen fibres between the bone and the implant. At the highest magnification, there was the appearance of a homogenous transition from the bone to the metal, suggesting a biological adhesion.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

N Katsikeris, R D Listrom, J M Symington. 1987. Interface between titanium 6,4 alloy implants and bone.. https://doi.org/10.1016/s0901-5027(87)80087-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrochemical characterization of albumin protein on Ti-6AL-4V alloy immersed in a simulated plasma solution.

The effect of oxygen and albumin on the electrochemical behavior of a Ti-6Al-4V alloy immersed in a simulated inorganic plasma (SIP) solution was studied with a rotating-cylindrical electrode configuration to focus on the surface/electrolyte reactions. Potentiokinetic scans and electrochemical impedance spectroscopy have been used to characterize the interface by determining the passive current density and capacitance. For the polarization scans, an albumin addition of 37.7 mg/cm(3) to the SIP solution (oxygenated and unoxygenated) decreased the passive current density, indicating a lowering of the corrosive rate. The surface capacitance for the Ti-6Al-4V alloy immersed in a SIP solution averaged 13 microF/cm(2), which transformed after albumin addition (37.7 mg/cm(3)) from a potential independent behavior to the capacitance ranging from 23 to 6 microF/cm(2) with increasing potentials from -800 to 1500 mV(SCE), respectively, indicative of albumin adsorption. Within the same potential range and albumin addition to oxygenated solutions, the capacitances expanded slightly with a similar decreasing trend from 31 to 6 microF/cm(2), although the capacitance depicts an interaction between the hydrated passive film and the adsorbed albumin from -550 to 500 mV(SCE) in which the capacitance plateaued at 15 microF/cm(2). The hydrated porous oxide film results from the porous rutile layer reacting with H(2)O(2) formed as an intermediary component of oxygen reduction at the Ti-6Al-4V surface. The passive film-albumin interaction would affect the processing of titanium alloys in their surface preparation for biocompatibility, as well as determining the reactivity of titanium alloys to proteins.

Alloys↗

Magnetic resonance imaging of phase transitions in nitinol.

Magnetic resonance images are prone to artifacts caused by metallic objects. Apart from being a source of image degradation, such artifacts can also provide information about the magnetic properties of the foreign object. In this work, we aim to explore the potential of magnetic resonance imaging to detect and characterize changes in magnetic properties of nitinol undergoing temperature- or strain-induced phase changes. A spin echo and a gradient echo method were used to measure the magnetization changes related to the phase transformations. Results of both methods were in agreement and in accordance with the independent measurements using a vibrating sample magnetometer. Magnetic resonance imaging turned out to be a suitable method to visualize and quantify magnetization and phase changes in situ. It is not restricted to a single imaging strategy and does not require any modification of the test object. The results indicate the potential of magnetic resonance imaging to provide direct feedback of the thermomechanical state of the alloy.

Alloys↗

A novel ordered nano hydroxyapatite coating electrochemically deposited on titanium substrate.

A novel porous nano hydroxyapatite (HA) coating has been prepared on commercially pure titanium substrate by a modified electrochemical deposition method. The physico-chemical and biological properties of the coating were characterized by SEM, XRD, FTIR, Raman, and in vitro cell culture test respectively. The SEM patterns show a uniform microporous morphology consisting of wirelike crystals at nanometer scale. It is suggested that under controlled deposition conditions, the primary HA nanowires grow and self-assemble to construct an ordered microporous nest-like morphology, thus to form a nano-micro two-level structure. The XRD results demonstrate that the HA nanowires are orderly arranged with their c-axis preferentially perpendicular to the substrate surface. The Raman and IR spectra affirm that the main component of the coating is well crystallized HA. An interdigitation phenomenon of the MG63 human osteosarcoma cells with the HA nanowires is observed in the in vitro test, indicating excellent biocompatibility and bioactivity for the prepared coating.