PubMed1999
Because proinsulin and insulin have different circulatory half-lives, the ratio of proinsulin to insulin in plasma depends on the dynamics of insulin secretion. This variation can potentially influence comparison of IMX assays and radioimmunoassays (RIAs) for [insulin], given that the antibody used in the IMX assay has negligible cross-reactivity with proinsulin compared to the 40% cross-reactivity with proinsulin of the antibody used in the RIA. Simulation of a simple mass balance model for insulin and proinsulin concentrations during an oral glucose tolerance test predicts that the ratio (R) of RIA to IMX insulin measurements of [insulin] should transiently decrease, pass through a minimum, increase past the initial value, pass through a maximum and eventually return to the initial value. Using time course specimens from patients, this pattern of variation in R was observed in the majority (12/16) of cases studied. The variation in R for time course specimens (CV = 26%) was significantly greater than for other specimens (fasting, random or undesignated; P < 0.05). Thus, when comparing IMX and RIA measurements of [insulin], variation in R for samples from differing states of dynamic insulin secretion contains a component that is attributable to dynamic changes in the ratio of [proinsulin]/[insulin] in plasma.