Search PubMed⌕ Search

PubMed · 3103255

[Congenital hypothyroidism. Current viewpoints and developments].

Abstract

Since 1978 neonatal screening on congenital hypothyroidism (CHT) is performed in The Netherlands. A combined T4 and TSH determination is used. This creates the possibility to detect secondary and tertiary hypothyroidism. The number of false-positive cases is relatively high. This number decreases by adjusting the method of screening. Recent studies show a CHT incidence of 1:2100 newborns. In about 25% of these cases the CHT appears to be transient. Proceeding from the screening on CHT several investigations presented in this review are in progress.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M H Gons, T Vulsma, J J de Vijlder. 1986. [Congenital hypothyroidism. Current viewpoints and developments].. https://pubmed.ncbi.nlm.nih.gov/3103255/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Inactivating mutations in the gene for thyroid oxidase 2 (THOX2) and congenital hypothyroidism.

BACKGROUND: Several genetic defects are associated with permanent congenital hypothyroidism. Immunologic, environmental, and iatrogenic (but not genetic) factors are known to induce transient congenital hypothyroidism, which spontaneously resolves within the first months of life. We hypothesized that molecular defects in the thyroid oxidase system, which is composed of at least two proteins, might be involved in the pathogenesis of permanent or transient congenital hypothyroidism in babies with defects in iodide organification, for which the oxidase system is required. METHODS: Nine patients were recruited who had idiopathic congenital hypothyroidism (one with permanent and eight with transient hypothyroidism) and an iodide-organification defect and who had been identified by the screening program for congenital hypothyroidism. The DNA of the patients and their relatives was analyzed for mutations in the genes for thyroid oxidase 1 (THOX1 ) and 2 (THOX2 ). RESULTS: The one patient with permanent and severe thyroid hormone deficiency and a complete iodide-organification defect had a homozygous nonsense mutation in the THOX2 gene that eliminates all functional domains of the protein. Three of the eight patients with mild transient congenital hypothyroidism and a partial iodide-organification defect had heterozygous mutations in the THOX2 gene that prematurely truncate the protein, thus abolishing its functional domains. CONCLUSIONS: Biallelic inactivating mutations in the THOX2 gene result in complete disruption of thyroid-hormone synthesis and are associated with severe and permanent congenital hypothyroidism. Monoallelic mutations are associated with milder, transient hypothyroidism caused by insufficient thyroidal production of hydrogen peroxide, which prevents the synthesis of sufficient quantities of thyroid hormones to meet the large requirement for thyroid hormones at the beginning of life.

Congenital Hypothyroidism↗

Neonatal thyroid-stimulating hormone concentrations in northern Sydney: further indications of mild iodine deficiency?

OBJECTIVE: To determine whether thyroid-stimulating hormone (TSH) concentrations in a large sample of neonates meet World Health Organization criteria for an iodine-replete population (< 3% of neonates with whole-blood TSH concentrations > 5 mlU/L), and, in a small subset of neonates, to examine the correlation between maternal urinary iodine and neonatal TSH concentrations. DESIGN: Cross-sectional study of neonatal whole-blood TSH values obtained as part of a routine newborn screening program. SETTING: Royal North Shore Hospital (RNSH) in northern Sydney. PARTICIPANTS: Two anonymous samples of neonates born at RNSH (1316 infants born between August 1998 and April 1999 and 1457 infants born between 1 March and 31 December 2000); and 84 infants whose mothers had attended RNSH between September 1998 and August 1999 and supplied a urine sample for iodine measurement. MAIN OUTCOME MEASURES: Iodine status of neonates (proportion with whole-blood TSH values > 5 mlU/L), and urine iodine concentrations of pregnant women. RESULTS: In the two large population samples of neonates, 8.1% (95% CI, 6.6%-9.5%) and 5.4% (95% Cl, 4.3%-6.6%), respectively, had whole-blood TSH values > 5 mlU/L (prevalence range for mild thyroid deficiency, 3%-19%). Comparing the TSH values of the 1316 anonymous infants and the 84 identified infants showed no difference between the proportions with TSH values > 5 mlU/L (8.1% v 10.7%, respectively; P = 0.39). Urine iodine concentrations in the 84 pregnant women indicated borderline mild iodine deficiency. TSH values in their 84 infants were positively correlated with maternal urine iodine concentrations. CONCLUSIONS: Our results suggest that the population of northern Sydney may have mild iodine deficiency. However, the expected relationship between maternal urine iodine levels and neonatal TSH concentrations was not found.

Congenital Hypothyroidism↗