Search PubMedSearch

PubMed · 3072647

Biological macromolecules explored by pattern recognition.

Abstract

Electron microscopy represents a very direct method for determining the structure of biological macromolecules, and complements both the well-established technique of X-ray crystallography (c.f. Blundell and Johnson, 1976) and the still in-its-infancy field of structure prediction (Kolata, 1986, Blundell et al., 1987). Our research has involved establishing a precise methodology based on computerised image analysis and pattern recognition to enhance the visibility of statistically significant structural features in electron images of isolated macromolecules. Our newly developed technique of angular reconstitution enables us to orient in three dimensions the commonly occurring projection forms of the macromolecules and thus perform a 3D reconstruction. In this paper, we describe the steps involved in determining the structure of a biological macromolecule by electron microscopy and image analysis, including pattern recognition and three dimensional reconstruction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M van Heel, G Harauz. 1988. Biological macromolecules explored by pattern recognition.. https://pubmed.ncbi.nlm.nih.gov/3072647/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A method for determining B1 field inhomogeneity. Are the biases assumed in heteronuclear relaxation experiments usually underestimated?

We describe a method allowing the determination of the effective B1 field amplitude distribution in a high-resolution NMR spectrometer. This method which can be adapted to almost any sequence, essentially consists of a mutation followed by a purging B0 gradient pulse. Experimental results obtained with this approach are described in homonuclear and heteronuclear cases. The experimental distributions are used to estimate the biases induced by B1 inhomogeneity, as well as the loss of RF power on heteronuclear transverse self-relaxation rate determination. In this type of measurement, the experimental biases induced on the intensities can be as large as 5% for long mixing times.

Image Processing, Computer-Assisted

J-multiplied HSQC (MJ-HSQC): a new method for measuring 3J(HNHalpha) couplings in 15N-labeled proteins.

A new method for the measurement of homonuclear 3J(HNHalpha) coupling constants in 15N-labeled small proteins is described. The method is based on a modified sensitivity enhanced HSQC experiment, where the 3J(HNHalpha) couplings are multiplied in the f1-dimension. The J-multiplication of homonuclear 3J(HNHalpha) couplings is based on simultaneous incrementation of 15N chemical shift and homonuclear coupling evolution periods. The time increment for the homonuclear coupling evolution period is chosen to be a suitable multiple (2N x t1) of the corresponding increment for 15N-shift evolution. This results in the splitting of the HSQC correlation in the f1-dimension by 2N x 3J(HNHalpha). Because the pulse sequence has good sensitivity and water suppression properties, it is particularly useful for natural abundance samples.

Image Processing, Computer-Assisted

Three dimensional image restoration in fluorescence lifetime imaging microscopy.

A microscope set-up and numerical methods are described which enable the measurement and reconstruction of three-dimensional nanosecond fluorescence lifetime images in every voxel. The frequency domain fluorescence lifetime imaging microscope (FLIM) utilizes phase detection of high-frequency modulated light by homodyne mixing on a microchannel plate image intensifier. The output signal at the image intensifier's phosphor screen is integrated on a charge coupled device camera. A scanning stage is employed to obtain a series of phase-dependent intensity images at equally separated depths in a specimen. The Fourier transform of phase-dependent data gives three-dimensional (3D) images of the Fourier coefficients. These images are deblurred using an Iterative Constrained Tikhonov-Miller (ICTM) algorithm in conjunction with a measured point spread function. The 3D reconstruction of fluorescence lifetimes are calculated from the deblurred images of the Fourier coefficients. An improved spatial and temporal resolution of fluorescence lifetimes was obtained using this approach to the reconstruction of simulated 3D FLIM data. The technique was applied to restore 3D FLIM data of a live cell specimen expressing two green fluorescent protein fusion constructs having distinct fluorescence lifetimes which localized to separate cellular compartments.

Image Processing, Computer-Assisted