Search PubMed⌕ Search

PubMed · 3048515

Automatic implantable defibrillators.

Abstract

The automatic implantable defibrillator was developed in the USA by Mirowski. This device automatically detects ventricular fibrillation or ventricular tachycardia and delivers a low energy (30 J) shock directly to the myocardium via patch electrodes on the epicardial surface or through a combination of a pericardial patch and an endocardial wire. These devices are being implanted in large numbers in the USA and represent a major contribution to the management and refractory ventricular arrhythmias. Unfortunately their high cost has limited their use in this country despite impressive clinical results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I G Crozier, D E Ward. 1988. Automatic implantable defibrillators.. https://pubmed.ncbi.nlm.nih.gov/3048515/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Is the orientation of the apical defibrillation paddle of importance during manual external defibrillation?

OBJECTIVE: Transthoracic impedance (TTI) is a factor determining the magnitude of the transmyocardial current during external defibrillation. Minimising TTI increases the chances of successful defibrillation. Most external defibrillation paddles are rectangular in shape and can, therefore, be placed in a transverse or longitudinal orientation. The apical paddle is often placed in a transverse orientation. This may theoretically result in a higher TTI than a longitudinal orientation because of poorer contact at the lateral paddle edges. We compared TTI with the apical paddle in both a transverse and longitudinal orientation. MATERIALS AND METHODS: Twenty sequential anaesthetised patients were studied. A pair of defibrillator paddles were instrumented to measure paddle force. TTI was recorded pre-operatively at end-expiration with the apical paddle in both longitudinal and transverse orientations. The sternal paddle was placed in a longitudinal orientation for all measurements. RESULTS: TTI decreased in both transverse and longitudinal orientations as paddle force increased. Transverse paddle orientation resulted in a significantly (P<0.01) higher TTI than longitudinal orientation at all paddle forces below 12 kg force. CONCLUSION: The longitudinal orientation of a rectangular defibrillation paddle provides a lower TTI than orientation horizontally.

Electric Countershock↗