Flexible ureterorenoscopy.

Abstract

The clinical applications of flexible ureterorenoscopes have fallen behind those of their rigid counterparts. Flexible endoscopes that possess a working channel and can also be employed for treatment have at last been developed. This instrument is particularly effective in the treatment of stones in the upper urinary tract, as it can easily follow mobile upper ureteral stones and calculi in the middle or lower renal calices, which are not as accessible with a rigid endoscope. It is important to remember not to exert too much force when inserting the instrument into the ureter, renal pelvis, or renal calices, and, if one remains calm, should the visual field become temporarily obscured, there should be little danger of damaging these structures. This method will probably be increasingly employed, not only for the treatment of stones in the upper urinary tract, but also for the removal of foreign bodies and the diagnosis and treatment of small pathologic conditions or lesions such as carcinoma in situ in which the roentgenologic presentation is unclear. For this expansion of instrument use to be ensured, it is necessary to improve the resolution of the fiberoptic endoscope image and increase the instrument's angulation capabilities, increase the range of accessories that can be employed with it, and also increase familiarity with the instruments on the part of urologists.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Y Aso, H Takayasu, N Ohta, A Tajima. 1988. Flexible ureterorenoscopy.. https://pubmed.ncbi.nlm.nih.gov/3043863/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Endoscopic controlled intramedullary fracture reduction. A case report about closed fracture reduction under visual control.

Intramedullary bone endoscopy (IBE) was introduced as a new endoscopic technique in the year 2002 to achieve and manipulate the medullary canal of long bone under direct visual control. We report on a patient with a proximal femur fracture, where the new technique of IBE was used for intramedullary fracture reduction under visual control for the first time. Thus, the intraoperative use of an image intensifier was reduced.

Endoscopes↗

Removal of a pellet from the left orbital cavity by image-guided endoscopic navigation.

In the cranio-maxillofacial field, computer-aided surgery based on computed tomography data is becoming increasingly important. Complex surgical procedures can be performed utilizing preoperative imaging to provide real-time localization of surgical instruments in the surgical field. Image-data-based navigation plays an ever-increasing role in cases of minimal invasive surgery. The case is presented here of a 58-year-old male patient referred after a hunting accident with a pellet in the left orbit. After transferring the preoperatively acquired computed tomography data to a commercially available navigation system, the bullet was removed through the original wound canal using an intraoperatively calibrated high-resolution endoscope.

Endoscopes↗

[Manipulator assisted endoscope guidance in functional endoscopic sinus surgery: proof of concept].

BACKGROUND: Functional endoscopic sinus surgery (FESS) is characterized by single-handed preparation and guidance of the endoscope by the nondominant hand. This results in an additional extension of operation time by up to 15% and ergonomic deficits. The aim of this study is the conception of an automated assistance system for FESS in view of the following questions: (1) Which degree of surgical automation is suitable for FESS? (2) Which design is suitable? (3) What are the properties of the technical system (planning, time, accuracy, precision) of the selected system? (4) Does the system offer potential for a clinical application? METHODS: In all 49 FESS were analyzed for surgical workflows. Measurement of the maximum forces within FESS was performed with 40 trials on an anatomical model. Three different mechanical systems were used in ten FESS and evaluated using the ICCAS Human-Machine Evaluation Scale. For realization of automated endoscope guidance an engine-driven and -braked manipulator (PA10-6c, Mitsubishi, Japan) was used. The technical parameters determined were expenditure of time for the preoperative planning of workspace, surgical accuracy and precision of the intraoperative endoscope positioning, maximal forces, and time. RESULTS: Concept-conditioned instrument changes amount to an average of 41.1 and 18.9% (5.21 min) time requirement for each FESS side. Maximum forces on the mucous membrane during a conventional FESS were measured at 9.8 N (5.9-9.8). Usability of the mechanical endoscope holder was estimated in 18 of 20 cases to be inferior to the standard procedure. The time needed for segmenting the intranasal workspace was 15.2 min (10.0-23.0). The maximum deviation of the automatically driven endoscope from a planned position amounted to 0.85 mm (manually 4.64 mm). The maximum force was measured with 1.1 N in the z direction (manually 9.8 N). Automated guidance of the endoscope to an intranasal position needed 7.25 s (6.4-7.9); manually 12.64 s (5.9-43.0). CONCLUSION: Guidance of the endoscope for FESS by an automated motor-driven system is possible. The conception which is based on workflow analysis favors a system with automatic definition of the workspace and a manual movement of the endoscope. The examined system offers a potential for clinical application. Definition of the automation level and development of a man-machine interface is more important than selection or reconstruction of a special manipulator for endoscope guidance in FESS from a surgical point of view.

Endoscopes↗