Search PubMed⌕ Search

PubMed · 30340

Increasing halothane concentrations reduce nitroprusside dose requirement.

Abstract

There has been no description of the hemodynamic dose-response relationship between halothane and sodium nitroprusside (SNP), although these drugs are used together frequently for induction of deliberate hypotension. Utilizing aortic root cannulation and thermister-tipped pulmonary artery catheterization, this relationship was studied in 6 beagles receiving a standard 100 microgram/kg infusion of SNP solution administered at 3 different infusion rates (5, 10, and 20 microgram/kg/min) while anesthetized with 3 different concentrations of halothane (0.5, 1, and 2%). Sodium nitroprusside infusion resulted in dose-related reductions in mean arterial pressure, systemic vascular resistance, and left ventricular stroke work. Increasing concentrations of halothane significantly potentiated the hypotensive effects of SNP. Cardiac output increase as the SNP infusion rate increased, whereas increasing the halothane concentration resulted in a reduction of cardiac output at each SNP infusion rate studied. Pulmonary artery wedge pressure was significantly reduced by SNP infusion at all 3 halothane concentrations, whereas mean pulmonary artery pressure was unchanged. Arterial pH fell in response to each SNP infusion, from 7.46 at the beginning of the study to 7.32 at the end (p less than 0.001). Sodium nitroprusside predictably induced hypotension during halothane anesthesia at the cost of a dose-related metabolic acidosis. Increasing the depth of halothane anesthesia afforded a greater percentage reduction in arterial pressure at each SNP infusion rate studied. Metabolic acidosis, however, developed no more rapidly at 2% halothane than it did at 0.5 or 1%.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R F Bedford. Increasing halothane concentrations reduce nitroprusside dose requirement.. https://doi.org/10.1213/00000539-197807000-00016

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effects of isoflurane, sevoflurane, and desflurane anesthesia on neurocognitive outcome after cardiac surgery: a pilot study.

BACKGROUND: Inhalation anesthetics such as isoflurane, sevoflurane, and desflurane are widely used in clinical practice; however, there is no study for comparing these drugs in cardiac surgery with respect to postoperative cognitive outcome and S100 beta protein (S100 BP) levels. In this study, we evaluated the effect of sevoflurane, isoflurane, and desflurane anesthesia on neuropsychological outcome and S100 BP levels in patients undergoing coronary artery bypass grafting (CABG) surgery with cardiopulmonary bypass (CPB). MATERIALS AND METHODS: Forty-two male patients were prospectively randomized and classified into 3 groups according to the volatile agents used; isoflurane, sevoflurane, desflurane. All patients had a sufficient education level to participate in neuropsychological testing and a normal carotid Doppler ultrasonography. Blood samples for analysis of S100 BP were collected before anesthesia (T1), before heparinization (T2), 15 minutes into CPB (T3), following protamine administration (T4), postoperatively (T5), 24 hours after the operation (T6), postoperative day 3 (T7), and postoperative day 6 (T8). The neuropsychological tests, including Mini-Mental State Examination (MMSET) and visual-aural digit span test (VADST), were administered 1 day prior to surgery and on the third and sixth postoperative days. RESULTS: The postoperative third and sixth day MMSET scores and third day visual-written subtest scores in the sevoflurane group were significantly lower than in the isoflurane and desflurane groups (P < .05). S100 BP levels increased with the beginning of anesthesia in the sevoflurane and desflurane groups. Although S100 BP decreased to baseline levels on postoperative day 1 in the sevoflurane group, this was significantly higher on the third and sixth days postoperatively in the desflurane group (P < .05). In the isoflurane group, the S100 BP level was significantly higher than the baseline level only after CPB (P < .05). CONCLUSION: Our study suggests that isoflurane is associated with better neurocognitive functions than desflurane or sevoflurane after on-pump CABG. Sevoflurane seems to be associated with the worst cognitive outcome as assessed by neuropsychologic tests, and prolonged brain injury as detected by high S100 BP levels was seen with desflurane.

Anesthesia, Inhalation↗