Search PubMed⌕ Search

PubMed · 298925

Keeping things in perspective.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C D Van Houweling. 1979. Keeping things in perspective.. https://pubmed.ncbi.nlm.nih.gov/298925/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

PdIr bimetallic nanozyme engineered metal-organic frameworks integrated dual-mode sensor toward Stx2 detection in food.

Shiga toxin II (Stx2) has attracted extensive attention due to its toxicity and pathogenicity, making the development of sensitive detection methods urgent. This study constructed a dual-mode sensing platform for the sensitive detection of Stx2 in food. Composite material UIO-66@PdIr with peroxidase-like activity and fluorescent properties was synthesized and combined with cDNA as the signal probe, while aptamer-modified magnetic beads served as the capture probe. Specific binding of Stx2 to the aptamer triggered the release of the signal probe, enabling colorimetric and fluorescence signal readout. The colorimetric mode showed a linear range of 0.05-100 ng/mL with an LOD of 0.039 ng/mL, and the fluorescence mode exhibited 0.01-1000 ng/mL with an LOD of 0.0097 ng/mL. Additionally, this method was successfully applied to the detection of Stx2 in food, and the recovery rates were 94.33% ∼ 102.20%. It indicated that the constructed sensor holds great practical potential for Stx2 detection.

Food Contamination↗

Optimization and evaluation of low-pressure gas chromatography-mass spectrometry for the fast analysis of multiple pesticide residues in a food commodity.

A fast method of analysis for 20 representative pesticides was developed using low-pressure gas chromatography-mass spectrometry (LP-GC-MS). No special techniques for injection or detection with a common quadrupole GC-MS instrument were required to use this approach. The LP-GC-MS approach used an analytical column of 10 m x 0.53 mm I.D., 1 microm film thickness coupled with a 3 m x 0.15 mm I.D. restriction capillary at the inlet end. Thus, the conditions at the injector were similar to conventional GC methods, but sub-atmospheric pressure conditions occurred throughout the analytical column (MS provided the vacuum source). Optimal LP-GC-MS conditions were determined which achieved the fastest separation with the highest signal/noise ratio in MS detection (selected ion monitoring mode). Due to faster flow-rate, thicker film, and low pressure in the analytical column, this distinctive approach provided several benefits in the analysis of the representative pesticides versus a conventional GC-MS method, which included: (i) threefold gain in the speed of chromatographic analysis; (ii) substantially increased injection volume capacity in toluene; (iii) heightened peaks with 2 s peak widths for normal MS operation; (iv) reduced thermal degradation of thermally labile analytes, such as carbamates; and (v) due to larger sample loadability lower detection limits for compounds not limited by matrix interferences. The optimized LP-GC-MS conditions were evaluated in ruggedness testing experiments involving repetitive analyses of the 20 diverse pesticides fortified in a representative food extract (carrot), and the results were compared with the conventional GC-MS approach. The matrix interferences for the quantitation ions were worse for a few pesticides (acephate, methiocarb, dimethoate, and thiabendazole) in LP-GC-MS, but similar or better results were achieved for the 16 other analytes, and sample throughput was more than doubled with the approach.

Food Contamination↗