Search PubMedSearch

PubMed · 2960362

Blood flow determinations utilizing digital densitometry.

Abstract

A method of obtaining relative and absolute blood flow measurements from digital densitometry was evaluated with a simulated vessel phantom and a hydrodynamic model. A digital vascular imaging system capable of acquisition in 512(2) and 1024(2) mode was used. Relative and absolute blood flow were measured using parameters derived from the densitometric curve. Since application of densitometric data to absolute flow measurements requires the vessel diameter, an algorithm for vessel size determination was created. Gray scale changes were demonstrated to be linearly related to contrast concentration. The variance of vessel size determination was significantly different in all combinations of 1024(2) and 512(2) imaging with 15 cm or 35 cm field size. The error in vessel size determination was significantly less using the larger 1024(2) matrix and the smaller 15 cm image intensifier field size, as shown by the smaller variance. In relative flow determinations, there was good correlation between the flow and four parameters of the densitometric curve with no significant differences between 512(2) and 1024(2) imaging. Absolute flow determinations had slightly lower correlation to actual flow but were not significantly different from relative flow determinations. Relative and absolute blood flow determinations can be performed adequately with either 512(2) or 1024(2) imaging. The increased accuracy in vessel size determination with 1024(2) imaging makes this high resolution system potentially preferable to determine absolute blood flow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J F Lois, N J Mankovich, A S Gomes. Blood flow determinations utilizing digital densitometry.. https://pubmed.ncbi.nlm.nih.gov/2960362/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Genetic, common environment, and individual specific components of variance for bone mineral density in 10- to 26-year-old females: a twin study.

Lean mass and areal bone mineral density at the lumbar spine, femoral neck, and total forearm were measured in 215 volunteer female twin pairs (122 monozygotic, 93 dizygotic), aged 10-26 years, using dual energy X-ray absorptiometry. The study was conducted in Melbourne from 1990 to 1994. Under the classic twin model, there was evidence for a genetic component of variation in bone mineral density, adjusted for age or for age and lean mass, at all sites. Adjusting for lean mass almost halved the genetic variances in the adolescent years of peak growth, during which genetic variances peaked. Genetic variances were reduced in the late teenage years and increased in early adulthood. The latter may reflect gene-environment interactions or covariation. Importantly, there was evidence for environmental effects shared by twins on lumbar spine and femoral neck bone mineral density, even when adjusted for lean mass as well as age. These were greatest during the late teenage years, abated over the years when pairs started to live apart, and appear to be independent of lean mass during adolescence but not in early adulthood. In summary, the genetic and environmental etiology of bone mineral density is more complex than previously thought.

Absorptiometry, Photon

Bone mass, lean mass, and fat mass: same genes or same environments?

The contributions of genetic and environmental factors to the association among bone mineral density (BMD), lean mass, and fat mass were assessed in the Sydney Twin Study of Osteoporosis (Australia), 1995-1996, in 57 monozygotic and 55 dizygotic female twin pairs of Caucasian background, aged 52.8 (standard deviation, 13) years. In multiple regression analysis, lean mass was a significant determinant of areal BMD; however, fat mass was a principal determinant of volumetric BMD. Univariate model-fitting analyses indicated that 80% and 65% of variance of lean mass and fat mass, respectively, were attributable to genetic factors. The estimated heritability of BMD for lumbar spine, femoral neck, and total body BMD was 78%, 76%, and 79%, respectively. Multivariate analyses suggested that, while the association between lean mass and fat mass was attributable mainly to environmental factors (re = 0.53, p < 0.01), the association among the three BMD sites was attributable to both genetic and environmental factors (rg = 0.64-0.75, p < 0.001; re = 0.57-0.70, p < 0.001). Furthermore, genetic factors that affect lean mass or fat mass have minor effects on BMD. It is concluded that lean mass and fat mass, as well as bone density, are under strong genetic regulation. However, the associations between BMD and fat mass or between lean mass and fat mass appear to be mediated mainly via environmental influences.

Absorptiometry, Photon

Bone mineral density in children and adolescents with diabetes mellitus type 1 of recent onset.

There is still controversy over the impact of diabetes control and duration on bone mass and growth parameters in children and adolescents with insulin-dependent diabetes mellitus (IDDM). The aim of this study was to assess bone mineral density (BMD) at axial and appendicular sites, in children with noncomplicated IDDM of recent onset, and its relation to metabolic control and auxological parameters (weight, height, and puberal stage). Fifty-five young Spanish IDDM, otherwise healthy patients (26 males, aged (SD 9.7 +/- 4.3 years) and 29 females, aged (SD 11.2 +/- 3.8 years) were studied. Duration of diabetes was 1-13.8 years. Two hundred eighty-two age-matched, healthy, Spanish children served as controls. HbA1 was assayed by high pressure liquid chromatography (HPLC) and BMD was measured using dual X-ray absorptiometry (DXA) densitometry at the spine and forearm. Results showed a Gaussian BMD distribution of patients according to sex and age, without sexual-stage differences. There was no correlation between BMD and glycated hemoglobin (average life disease or last HbA1 values) or duration of the disease; moreover, no differences in bone mass were found between <3 and >/=3 years of disease duration. Diabetes impact index (mean HbA1 x duration of disease in months) showed no significant influence of diabetes control on BMD. We could not demonstrate any impact of diabetes on BMD and growth parameters in children with IDDM of short duration.

Absorptiometry, Photon