Search PubMedSearch

PubMed · 295666

A loopformer for archwires.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H D Davis. 1979. A loopformer for archwires.. https://doi.org/10.1179/bjo.6.1.3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Distal end cutters--efficiency, safety and design.

This investigation aimed to evaluate the efficiency of a range of different distal end cutters in cutting and holding the ends of orthodontic arch wires. Fourteen different types of distal end cutter were used to cut a range of orthodontic arch wires under standard conditions. The arch wires comprised nickel-titanium and stainless steel wires of different dimensions, as well as twist flex and coaxial wires. The number of times each wire was successfully cut and held by each cutter was recorded. Significant differences in performance between the cutters were noted, particularly in holding the cut distal ends. Small diameter nickel-titanium wires were significantly less well held than heavier grade or stainless steel wires. Twist flex and coaxial wires were less easily cut cleanly than nickel-titanium and plain stainless steel wires.

Dental Alloys

X-ray diffraction studies of as-cast high-palladium alloys.

OBJECTIVES: The purpose of this study was to use x-ray diffraction (XRD) to investigate four representative high-palladium alloys in the as-cast condition and obtain new information about the metallurgical phases. METHODS: Two Pd-Cu-Ga alloys and two Pd-Ga alloys were cast into plate-shaped specimens (20 mm x 1.5 mm) which were bench-cooled. Polished and etched specimens were analyzed using two different x-ray diffractometers and CuKa radiation. RESULTS: All four alloys exhibited strong XRD peaks for the face-centered cubic (fcc) palladium solid solution matrix, and variations in the lattice parameter were consistent with alloy compositions. Comparison of the relative peak intensities for the alloys and the pure palladium powder standard indicated that the as-cast microstructures had preferred crystallographic orientation. Because the two Pd-Cu-Ga alloys contained appreciable amounts of near-surface lamellar interdendritic or eutectic constituents, it was possible to determine previously unreported XRD peaks for the Pd2Ga phase in these alloys. Low-intensity peaks in the Pd-Ga alloys were attributed to small amounts of secondary phases observed in the microstructures. SIGNIFICANCE: Knowledge of the metallurgical structures of these high-palladium alloys can be important for interpretation of microstructural observations, mechanical properties, corrosion behavior and clinical performance.

Dental Alloys