Search PubMed⌕ Search

PubMed · 288706

An alternative restoration method.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G L Jackson. 1978. An alternative restoration method.. https://pubmed.ncbi.nlm.nih.gov/288706/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure.

This in vitro study compared the depth of cure obtained with six quartz tungsten halogen and light-emitting diode curing units at different exposure times and light tip-resin composite distances. Resin composite specimens (Tetric Ceram, A3; diameter 4 mm, height 6 mm) were exposed from 0-, 3-, and 6-mm distance. The curing units (200-700 mW/cm2) were used for standard (20 and 40 s), pulse-delay mode (initial exposure of 3 s at 200 mW/cm2, followed by a resting period of 3 min and a final exposure of 10 or 30 s at 600 mW/cm2), or soft-start curing (40 s; exponential ramping). Curing depth was determined by measurement of Wallace hardness for each half millimeter starting at 0.5 mm from the top surface. For each specimen, a mean H(W) value was calculated from the H(W) values determined at the depths of 2.0 mm and less (0.5, 1.0, 1.5, and 2.0 mm, respectively). The depth of cure for each specimen was found by determining the greatest depth before an H(W) value exceeding the minimal H(W) value by 25% occurred. For all curing units, an increase in exposure time led to significantly higher depth of cure. Increasing the light tip-resin composite distance significantly reduced the depth of cure. With a light tip-resin composite distance of 6 mm, median values of depth of cure varied between 2.0 and 3.5 mm following a 20-s (or 3+10 s) exposure and between 3.0 and 4.5 mm following a 40-s (or 3+30 s) exposure. The composite situated above the depth of cure value cured equally well with all curing units. At both exposure times, Luxomax resulted in the significantly lowest depth of cure, and Astralis 7 yielded significantly higher depth. At both exposure times, a significant linear correlation was found between the determined power densities of the curing units and the pooled depth of cure values obtained. It seems that for the resin composite tested, the recommended exposure time of 40 s per 2-mm increment may be reduced to 20 s, or that increments may be increased from 2 to 3.5 mm. It may be that the absolute values of depth of cure found are material specific, but we believe that the relationships found between curing units, between exposure times, and between light guide distances are universal.

Composite Resins↗

Thermal risks from LED- and high-intensity QTH-curing units during polymerization of dental resins.

The aim of this study was to test the ability of an infrared (IR) camera to assess temperature changes and distributions in teeth below restorations when quartz-tungsten-halogen (QTH) and light-emitting diode (LED) curing lights were used to photopolymerize the restorative material. Our hypothesis was that the higher power density and broader spectral distribution of the QTH source would cause greater increases in tooth temperature than the LED source, and that these differences would be best demonstrated with the IR camera. Cavities were prepared on human third molars and restored with a resin composite restorative material. The material was light-cured using three light-curing sources using several exposure times. The external (outside the tooth) and internal (inside the pulp chamber) temperature changes during polymerization of the composite material were recorded over 360 s with thermocouples and an IR camera. Using thermocouples the maximum increase in external temperature (+17.7 degrees C) was reported for the Swiss Master light after 20 s of curing time while the minimum temperature rise (+7.8 degrees C) was reported for the Freelight 2. Whereas a 2.6 degrees C increase in internal temperature was observed after curing 20 s with the Freelight 2, 7.1 degrees C was reported after 60 s of light exposure to Astralis 10. Infrared images showed similar trends in external-internal rises in temperature as the thermocouples, although temperatures measured by the IR were generally higher. These results indicate that the higher power density QTH sources caused greater increases in tooth temperatures than the LED source and that thermocouples may underestimate the heat applied to the tooth.

Composite Resins↗

Elastic modulus of resin-based dental restorative materials: a microindentation approach.

This research aimed to determine the elastic modulus of resin-based dental composite restoratives using the microindentation test method. Results were then compared with those obtained with the ISO three-point bending test method. Five materials from the same manufacturer (3M ESPE) were selected for the study. They included microfill (A110), minifill (Z100 and Filtek Z250), poly-acid modified (F2000), and flowable (Filtek Flowable [FF]) composites. The indentation moduli of the composites were determined using a custom-designed microindentation test set up after conditioning in water at 37 degrees C for 1 week and 1 month. The indentation test was carried out at peak load of 10 N and Oliver & Pharr's method was used to determine the maximum projected contact area. Data was analyzed using ANOVA/post-hoc Scheffe's test at significance level 0.05 and Pearson's correlation at significance level 0.01. The mean indentation modulus ranged from 5.80 to 15.64 GPa and 5.71 to 15.35 GPa at 1 week and 1 month, respectively. At both time periods, the indentation modulus of Z100 was significantly higher than all other materials. F2000 was significantly higher than Z250, which was significantly stiffer than A110 and FF. The rankings were in good agreement with the ISO flexural test. A significant, positive, and strong correlation (r = 0.93 and 0.94 at 1 week and 1 month, respectively) in modulus between ISO three-point bending and microindentation test methods was observed. In view of the small specimen size and good reproducibility, the microindentation reflects a potential test method for determining the elastic properties of dental composite restoratives.

Composite Resins↗