Search PubMedSearch

PubMed · 2876023

Acid rules--or does it?

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J J Misiewicz. 1986. Acid rules--or does it?. https://pubmed.ncbi.nlm.nih.gov/2876023/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of post-column fluorescence derivatization to develop a liquid chromatographic assay for ranitidine and its metabolites in biological fluids.

Ranitidine and its main metabolites, ranitidine N-oxide and ranitidine S-oxide, were determined in plasma and urine after separation using reversed-phase liquid chromatography. The mobile phase consisted of an initial isocratic step with 7:93 (v/v) acetonitrile-7.5 mM phosphate buffer (pH 6) for 8 min, followed by a linear gradient up to a 25:75 (v/v) mixture over 1 min. Detection was carried out by a post-column fluorimetric derivatization based on the reaction of the drugs with sodium hypochlorite, giving rise to primary amines that reacted with o-phthalaldehyde and 2-mercaptoethanol to form highly fluorescent products. The calibration graphs, based on peak area, were linear in the range 0.1-4 microg/ml for all drugs. The detection limits were 30, 41 and 32 ng/ml (8.6, 12.5 and 9.1 pmol) for ranitidine S-oxide, ranitidine N-oxide and ranitidine, respectively. Chromatographic profiles obtained for plasma and urine samples showed no interference from endogenous compounds.

Anti-Ulcer Agents

Simple and robust high-performance liquid chromatographic method for the determination of ranitidine in microvolumes of human serum.

A simple robust high-performance liquid chromatographic method is described for the determination of ranitidine in microvolumes of human serum. The drug of interest was isolated using liquid-liquid extraction with dichloromethane and back-extraction with 0.1% phosphoric acid and separation was obtained using a reversed-phase column under isocratic conditions, with ultraviolet detection at 313 nm. Intra-day and inter-day coefficients of variation ranged from 1 to 6% and 3 to 10%, respectively. Accuracy of the assay was less than 10% at all concentrations. The limit of detection and the limit of quantitation were 2 and 7 ng/ml, respectively. The linearity was assessed in the range 10-1000 ng/ml. It was shown that a group of common drugs co-administered with ranitidine did not interfere with its determination. The applicability of this method for the pharmacokinetic study of ranitidine following i.v. infusion in patients was demonstrated using only 100 microl of serum. The ruggedness of the assay was demonstrated over a three-year period.

Anti-Ulcer Agents