Search PubMed⌕ Search

PubMed · 2811566

Should there be a formal mechanical-optic-electronic biomedical-engineering program?

Abstract

To progress in the development of laser medicine and laser surgery, multidisciplinary efforts are required. One important phase in its development is the laser biomedical engineering program being offered following the basic laboratory research. Some of this type of programming is present today, but more development is needed for a formal program offering crossfertilization between engineering and medical uses. Therefore, a formal program is being proposed, which will be reviewed by mixed groups over a period of time. A final recommendation will indicate whether to go ahead with this revision of the program, to wait for further development of the program, or to maintain the status quo. The relationship of technical training for technicians in laser biomedical engineering is also reviewed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Goldman. 1989. Should there be a formal mechanical-optic-electronic biomedical-engineering program?. https://doi.org/10.1002/lsm.1900090502

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Optimal design of non-Newtonian, micro-scale viscous pumps for biomedical devices.

The present paper addresses the numerical optimization of geometrical parameters of non-Newtonian micro-scale viscous pumps for biomedical devices. The objective is to maximize the mass flow rate per unit of shaft power consumed by the rotor when an external pressure load is applied along the channel that houses the rotor. Two geometric parameters are considered in the optimization process: (i) the height of the channel that houses the rotor (H) and (ii), the eccentricity (epsilon) of the rotor. Three different micro-scale viscous pump configurations were tested: a straight-housed pump (I-shaped housing) and two curved housed pumps (L- and U-shaped housings). The stress-strain constitutive law is modeled by a power-law relation. The results show that the geometric optimization of micro-scale viscous pumps is critical since the mass flow rate propelled by the rotor is highly dependent on epsilon and H. Numerical simulations indicate that mass flow rate is maximized when epsilon approximately 0, namely when the rotor is placed at a distance of 0.05 radii from the lower wall. The results also show that micro-scale viscous pumps with curved housing provide higher mass flow rate per unit of shaft power consumed when compared with straight-housed pumps. The results are presented in terms optimized dimensions of all three configurations (i.e., H(opt) and epsilon(opt)) and for values of the power-law index varying between 0.5 (shear thinning fluids) and 1.5 (shear-thickening fluids).

Biomedical Engineering↗