Search PubMed⌕ Search

PubMed · 2711346

Recent developments in neutron capture therapy.

Abstract

The conditions for the possible initiation of clinical trials with neutron capture therapy at a number of locations in the U.S. is reviewed. There are several new technical developments or plans at the Brookhaven Medical Research Reactor (BMRR), the Power Burst Facility (PBF) at INEL, the Massachusetts Institute of Technology Reactor (MITR) and the Georgia Institute of Technology Research Reactor (GTRR). Emphasis is on the development of epithermal beams for the treatment of deepseated tumors with neutron fluxes in between 10(9) to 10(10) n/cm2s. Therapeutic dose gains, defined as the ratio of tumour dose to maximum normal tissue dose in the treatment volume are expected to be between 2 and 4, depending on the degree of suppression of fast neutron dose. Boron concentrations considered in this case in the tumour are around 35 micrograms 10B/g and tumour/normal tissue concentrations are around 10. The compound development throughout three generations is discussed. The compound proposed nowadays, Na2B12H11SH (or BSH), employed in the treatments in Japan, will likely be replaced in the future by analogous of biomolecules being enriched in the tumour by physiological pathways. Examples are p-boronophenylalanine or boronated porphyrius. The most promising solution envisaged would be the employment of tumour cell specific brononated monoclonal antibodies. Finally the mode of therapy is discussed which will likely be based on a fractioned scheme, to achieve optimized results.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R G Fairchild, F Wheeler, D N Slatkin, J Coderre, P Micca, B Laster, S B Kahl, P Som, I Fand. 1989. Recent developments in neutron capture therapy.. https://pubmed.ncbi.nlm.nih.gov/2711346/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Monte Carlo calculations of thermal neutron capture in gadolinium: a comparison of GEANT4 and MCNP with measurements.

GEANT4 is a Monte Carlo code originally implemented for high-energy physics applications and is well known for particle transport at high energies. The capacity of GEANT4 to simulate neutron transport in the thermal energy region is not equally well known. The aim of this article is to compare MCNP, a code commonly used in low energy neutron transport calculations and GEANT4 with experimental results and select the suitable code for gadolinium neutron capture applications. To account for the thermal neutron scattering from chemically bound atoms [S(alpha,beta)] in biological materials a comparison of thermal neutron fluence in tissue-like poly(methylmethacrylate) phantom is made with MCNP4B, GEANT4 6.0 patch1, and measurements from the neutron capture therapy (NCT) facility at the Studsvik, Sweden. The fluence measurements agreed with MCNP calculated results considering S(alpha,beta). The location of the thermal neutron peak calculated with MCNP without S(alpha,beta) and GEANT4 is shifted by about 0.5 cm towards a shallower depth and is 25%-30% lower in amplitude. Dose distribution from the gadolinium neutron capture reaction is then simulated by MCNP and compared with measured data. The simulations made by MCNP agree well with experimental results. As long as thermal neutron scattering from chemically bound atoms are not included in GEANT4 it is not suitable for NCT applications.

Fast Neutrons↗

Particle matters.

Explore the source record for details and available documents.

Fast Neutrons↗

PIN silicon diode fast neutron detector.

Two batches of diodes, with different structural ratios (the ratio of area and thickness), were made using different manufacturing processes. The energy response of the first batch to 15 kinds of monoenergetic neutrons ranging from 180 keV to 17.56 MeV was tested, and the neutron source response of both batches to 239Pu-Be neutron source was measured. The energy deposition in the diodes irradiated by 1 keV to 20 MeV monoenergetic neutrons was calculated with simulation procedure. The response curve of the experimental results showed an approximately similar trend to that of theoretical computation. Based on the results of the neutron source response experiments, it was concluded that the response of fast neutron varied linearly with the structural ratio of the detectors.

Fast Neutrons↗