Search PubMedSearch

PubMed · 2700446

[Titanium casting using the Titaniumer. Casting technic is not yet final].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Geis-Gerstdorfer, H Weber, A Simonis, M Echkardt, D Haselberger. 1989. [Titanium casting using the Titaniumer. Casting technic is not yet final].. https://pubmed.ncbi.nlm.nih.gov/2700446/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Clinical evaluation and microstructural analysis of a direct placement gallium restorative alloy.

OBJECTIVES: The objective of this study was to assess the clinical performance of a direct placement gallium alloy sealed with an established dentine adhesive system. In addition, microanalysis of a few gallium restorations that failed in clinical service was performed. Clinical factors such as pulpal sensitivity, fracture of the restoration and of the tooth, marginal deterioration, and tarnish were assessed. METHODS: Sixty-five restorations of Galloy and 62 of Tytin (49 and 51 Class II restorations, respectively) were placed according to a predetermined scheme for randomisation in 37 patients by two operators using rubber dam isolation. For the Galloy restorations, the enamel and dentine were etched, and then sealed with PAAMA 2 dentine adhesive according to the manufacturer's instructions. After carving, PAAMA 2 was applied to the Galloy and light-cured. Cavity preparations for Tytin received no adhesive sealer. All restorations were polished at least 24 h post-operatively. Microstructural analysis of retrieved fragments of failed restorations was conducted using electron probe microanalysis. RESULTS: At 1 year, only one Tytin restoration was found to have failed due to an isthmus fracture. The remaining restorations of Tytin were intact with no reported sensitivity. Of the 65 Galloy restorations placed, 28 had to be removed, including restorations in teeth, which were symptomatic, non-vital and/or fractured, and teeth with fractured restorations. Tarnish was present on many of the Galloy restorations. Retrieved fragments of failed Galloy restorations exhibited a dark surface at the pulpal wall interface and small cracks were observed in that surface. Internal cracks and extensive corrosion was observed using the microprobe. Gallium oxides and chlorides were identified as the predominant corrosion products. CONCLUSIONS: The gallium alloy, Galloy, sealed with PAAMA 2 dentine adhesive system demonstrated a high clinical failure rate.

Dental Alloys

The effect of surface treatments of nickel-titanium files on wear and cutting efficiency.

OBJECTIVES: This study was designed to verify whether nitridation treatment of the cutting surfaces resulted in surface or subsurface changes that produced an increase in the resistance to wear in nickel titanium (NiTi) endodontic files. STUDY DESIGN: Some experimental samples were exposed to ionic implantation by using 150 keV of nitrogen ions and doses of 1 x 10(17) ions per cm(2). Other samples were exposed to thermal nitridation processes performed for 480 minutes at 500 degrees C temperature. Control samples were not exposed to any process. The chemical composition of the surface layers of each sample was determined by means of x-ray photoelectron spectroscopy. The cutting efficiency was tested on an endotraining bloc. RESULTS: The experimental instruments showed in-depth distributions of chemical composition that were different from those seen in the control group; thermal-nitridated instruments demonstrated a surface ratio of nickel to titanium of 0.5. Implanted samples had a higher N/Ti ratio (1.2); this ratio may be due to the presence of a layer of titanium nitride. Samples in the experimental groups showed an increase in cutting ability as compared with the controls. CONCLUSIONS: Thermal nitridation and nitrogen-ionic implantation treatment of nickel-titanium files produced a higher wear resistance and an increased cutting capacity.

Dental Alloys

The CrescoTi Precision method: description of a simplified method to fabricate titanium superstructures with passive fit to osseointegrated implants.

Casting distortion and inadequate handling in the dental laboratory are 2 factors that can cause misfit between a cast framework and the implant analogs in the master cast. This article describes the CrescoTi Precision procedure, which has been developed for correction of misfit between cast titanium frameworks and supporting dental implants. The simplicity and accuracy of the procedure appear to demonstrate technical progress toward obtaining optimal precision of fit of the superstructure components, thereby eliminating stress forces that may be transformed to the peri-implant bone.

Dental Alloys