High frequency oscillators with adjustable waveforms: practical aspects.

Abstract

We have shown that several types of high frequency oscillator can be modified to produce non-sinusoidal flow patterns. We are convinced that the ability to adjust the wave form is a useful feature of a high frequency ventilator. As the required energy is related to (frequency) all the machines we have examined are large, heavy and noisy. Some problems could probably be overcome by engineering skill. For this reason we have not presented detailed power charts of our machines (built mostly by us). However, one has to admit that none of the devices is sophisticated enough to satisfy a physician who is not enthusiastic for high frequency ventilation. On the other hand, we have treated several patients suffering from bronchiectasis using a linear motor piston heavier than the patient. Asymmetric oscillations helped to clear the airways of purulent sputum. Despite all the noise and unsophisticated appearance of the machine, it was accepted well by the patients because they felt relief. This suggests that, regardless of all obstacles, research in HFV technology should be continued.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Freitag, M Schroer, J Bremme. 1989. High frequency oscillators with adjustable waveforms: practical aspects.. https://doi.org/10.1093/bja%2F63.7.38

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of two repositioning devices used during radiation therapy for Hodgkin's disease.

PURPOSE: Patients irradiated for Hodgkin's disease are fixed in an immobilization cradle to improve repositioning. In the early 1990s, we changed our cradle system from a "short" upper torso cradle to an extended near-total body cradle that also includes the lower torso and thighs. In this study, we assess the impact of the extended cradle on the reproducibility of patient repositioning during irradiation of Hodgkin's disease. METHODS AND MATERIALS: A total of 782 port films of 56 patients treated immediately before and after the change-over were studied to assess positioning reproducibility. Patients treated prior to 1993 were positioned in the short cradle, while those treated 1993 and later were positioned in the extended cradle. All treatment were delivered via anterior and posterior fields and treatment areas above and below the diaphragm were considered separately and together. All treatment fields were simulated and the field shape was designed on anterior and posterior radiographs. Discrepancies in field placement between the simulation radiographs and subsequent port films were noted by a radiation oncologist and requests for position adjustment (both translational and rotational shifts) were noted. The number, magnitude, and direction of any physician-requested position adjustment on port films were retrospectively reviewed. For the purpose of scoring the frequency of field misplacements, when an adjustment was noted on two port films taken during the same treatment session (i.e., a left shift on both an anterior and a posterior port film), it was scored as only one event. A two-tailed chi-square test was used to compare the differences in requested shifts in the two patient groups. RESULTS: The study population consisted of 56 patients (31 short and 25 extended cradle) representing 92 treatment sites. A total of 782 port films representing 450 treatment setups were analyzed (292 above and 158 below the diaphragm). When all port films above the diaphragm (mostly mantle fields) are considered, position adjustments were requested in 13.4% (21 out of 157) of treatment setups with the upper torso cradle and in 5.9% (8 out of 135) of treatment setups with the extended cradle (p = 0.054). When all port films below the diaphragm (mostly paraaortic/spleen and pelvic fields) are considered, position adjustments were requested in 33.8% (27 out of 80) of treatment setups with the upper torso cradle and in 16.7 % (13 out of 78) of treatment setups with the extended cradle (p = 0.056). A reduction in the frequency of both translational and rotational adjustments were seen. When both treatment sites are combined, position adjustments were requested in 20.3% (48 out of 237) of treatment setups with the upper torso cradle and in 9.9% (21 out of 213) of treatment setups when the extended cradle was used (p = 0.0086). CONCLUSIONS: The extended cradle provides superior repositioning of patients undergoing radiation therapy for Hodgkin's disease. Differences observed in setup accuracy in this study underscore the importance of aggressive immobilization of patients with Hodgkin's disease. Increased accuracy of daily setup may provide an opportunity to improve the therapeutic ratio both by increased likelihood of tumor control and decreased risk of normal tissue complications.

Equipment Design

E-speed film.

Explore the source record for details and available documents.

Equipment Design